HP Integrity rx1600 Operation and Maintenance Guide
Event, Error, and Warning Messages
EFI Error and Warning Messages
Appendix B
198
0120 - BMC Chass cntrl 00-12:70:A3 80:03 2003-10-31 22:24:35
0130 - ACPI State S5 (off) FA-22:6F:05 2003-10-31 22:24:35
0140 - Fan 1 (PSU) Fail (crit) 11-0A:07:02 2003-10-31 22:25:00
0150 - BMC Chass cntrl 00-12:70:A3 81:03 2003-10-31 22:25:24
0160 - BMC LPC reset 00-12:70:02 2003-10-31 22:25:26
0170 - Fan 1 (PSU) OK 11-0A:07:00 2003-10-31 22:25:26
0180 - ACPI State S0 (on) FA-22:6F:00 2003-10-31 22:25:27
0190 - SFW Boot start 00-1D:0A:00 2003-10-31 22:25:27
01A0 2 CPU1 Boot start 00063 DT 04 0000000000000000
01B0 2 CPU1 Boot start 00063 Time 2003-10-31 22:25:27
01C0 - BMC LPC reset 00-12:70:02 2003-10-31 22:25:29
01D0 - SEL Time Set Set FD-C0:03:01 2003-10-31 22:25:39
01E0 3 CPU0 Mem pair mis 0030B DT 06 0000000000000B0A
01F0 3 CPU0 Mem pair mis 0030B Time 2003-10-31 22:25:40
0200 3 CPU0 Mem thermal 0026F DT 06 FFFFFFFF00FFFF72
0210 3 CPU0 Mem thermal 0026F Time 2003-10-31 22:25:41
0220 - SFW FW error 00-0F:70:40 3F:-- 2003-10-31 22:25:41
0230 7 CPU0 Mem not fnd 000D1 DT 00 0000000000000000
0240 7 CPU0 Mem not fnd 000D1 Time 2003-10-31 22:25:41
0250 - SFW FW error 00-0F:70:40 3F:-- 2003-10-31 22:25:41
0260 7 CPU0 Halt boot 00037 DT 04 000000000000000F
0270 7 CPU0 Halt boot 00037 Time 2003-10-31 22:25:41
Each column in the log contains a different data field:
1. Record ID.
2. Severity for E0 messages.
3. Generator id or sensor reporting the event.
4. Text description of events.
5. Sensor number-Sensor Type:Event Type:Data1 fields for type 02 msgs (triplet) event id for E0 msgs.
6. Data2 and Data3 for type 02 msgs (if applicable) or Data type for E0 messages.
7. Timestamp or extended data specific to the event.
Accessing the logs with MP commands
The SEL and FPL data can also be accessed from the MP logs using the MP card SL command.