HP Integrity rx1600 Operation and Maintenance Guide
Event, Error, and Warning Messages
EFI Error and Warning Messages
Appendix B
199
The v command (view mode configuration) determines the format of the display:
• hex mode
• text mode
• keyword mode
Hex Mode Example:
0x5E800A7A00E00FD0 0000000000000003
Text Mode Example:
Log Entry 1: 31 Oct 2003 21:34:17
Alert Level 2: Informational
Keyword: Type-02 0a0700 657152
Cooling unit OK
Logged by: Baseboard Management Controller; Sensor: Cooling Device - Fan 1 (PSU)
Data1: transition to OK
0x203FA2D559020020 FFFF0007110A0300
Log Entry 0: 31 Oct 2003 21:33:21
Alert Level 3: Warning
Keyword: Type-02 0a0701 657153
Cooling unit warning
Logged by: Baseboard Management Controller; Sensor: Cooling Device - Fan 1 (PSU)
Data1: transition to Non-Critical from OK
0x203FA2D521020010 FFFF0107110A0300
Keyword mode example:
13 BMC 2 0x203E5F914A0200E0 FFFF010944080300 Type-02 080901 526593 28 Feb 2003 16:41:46
14 SFW 0 2 0x5680006300E000F0 0000000000000000 BOOT_START 28 Feb 2003 16:41:46
15 BMC 2 0x203E5F914B020110 FFFF027000120300 Type-02 127002 1208322 28 Feb 2003 16:41:47