HP Integrity rx1600 Operation and Maintenance Guide
Event, Error, and Warning Messages
EFI Error and Warning Messages
Appendix B
200
System Specific Events
OEM SensorType 12, EventType 71
Missing components are determined at the time of a power-on request, cause a failure in the request, and cause the event to be
logged.
Chassis Control Event Codes
For BMC rev 1.41+, an SEL event will be logged for each ChassisControl event, whether it’s generated by an IPMI request, or
a sensor event.
Later revisions of MP firmware recognize the triplet (12:70:A3) as ChassisControl.
The EventData fields are:
• Data1: 0xA3 (indicating OEM data in Data2 and Data3, and OEM offset 3)
• Data2:
• [7] 0 = Request generated by a Sensor Event
• 1 = IPMI request
•[6-4] Reserved
• [3-0] ChassisControl command
• Data3: Sensor Number or IPMI Request Origin
Table B-2 Missing Components
Data 2 Data 3 Missing Component
0x0C-0D Power Pod 0-1
0x20-21 CPU 0-1
0x1E 0x01 Cooling Unit 1
0x1E 0x01 Cooling Unit 2
0x1E 0x03 Cooling Unit 3
Table B-3 Chassis Control Commands
Command Description
0x00 Hard Power Down
0x01 Power Up
0x03 Hard Reset
0x04 NMI/TOC/INIT
0x0D Soft Shutdown and Restart
0x0E Soft Shutdown