HP Integrity rx1600 Operation and Maintenance Guide
Event, Error, and Warning Messages
EFI Error and Warning Messages
Appendix B
202
Events Without Sensors
The BMC logs these events with a “sensor number” of 0; there is no matching SDR entry.
Table B-6 Events Without Sensors
Triplet Event data 2 data 3 Notes
10:70:64 SEL almost full 1F %full The BMC logs this when the
SEL is 75% full
12:70:64 BMC entering firmware update mode
12:70:05 SFW flash Inlock
12:70:06 Front panel lock
12:F0:06 Front panel unlock
12:70:64 Firmware update application: starting
component update
12:70:64 Firmware update application: ending
component update
12:70:80 BMC entering special mode Mode – Mode is a bit-map:
Bit 0: Shmoo
Bit 1: MfgTest
Bit 2: Shutdown override
Bit 3: Fixed fan speed
Bit 4: Mfg
Bits 7-5: unused, set to 0
12:70:A1 BMC firmware initializing Major FW rev. Minor FW rev.
1D:70:00 BMC Cold Reset
1D:70:01 BMC Warm Reset
1D:70:02 BMC Cold Reset after SDRR update