hp Server Shipping Bracket Installation
© Copyright 2004
Hewlett-Packard Development Company, L.P.
June 2004 v1
Printed in the U.S.A.
hp Server Shipping Bracket Installation
The following includes steps to install a shipping bracket in the hp Integrity rx1600 Server.
Related Documents
Complete server installation and removal instructions can be found in both of the following sources:
· The hp Server Installation Guide, on the hp Server Documentation CD-ROM shipped with your hp Server
· The hp Installation Guide, Mid-Weight Slide Kit, 5065-7291
· Documents for your hp Server can be viewed and printed from the hp web site:
h
ttp://www.docs.hp.com
Tool Required
T25 Torx Driver
Installing the Shipping Bracket
The following installation procedure is for rack-mounted models of the server.
Install a Main Bracket in the rack after every 20 servers installed with this procedure or below each server that is not part
of a supported stack. Repeat Step 1 through Step 5 to install each Main Bracket in the rack.
1. Install 8 M5 clip nuts (0590-2318) in the space below the lowest server in the rack, two each on each side of the front
and back rails. Install the clip nuts in the top and bottom holes within the space as shown in Figure 1.
Figure 1. Clip Nut Installation on hp Rack System E
2. Install each rear side bracket using two M5 (0515-3019) screws shown in Figure 2. Do not fully tighten the screws.
L (left) and R (right) markings indicate the correct side for installation as seen from the front of the rack. The support
pin should be facing inward.