Operations Guide, Fourth Edition - HP Integrity rx1620
A Event, Error, and Warning Messages
This appendix contains event, error and warning information for the hp Integrity rx1620 Server
system:
• Extensible Firmware Interface (EFI) error and warning messages
• System Event Log (SEL) and Forward Progress Log (FPL) Entries
EFI Error and Warning Messages
EFI error and warning messages are displayed on the console as part of the boot process. They
can also be retrieved via the info warningsEFI command.
Table A-1 EFI Error and Warning Messages
SolutionError/Warning MessageError
Number
Incorrect I/O configuration. Contact the HP
Support center for assistance.
Insufficient resources to assign to one or more I/O
devices
2
Incorrect I/O configuration. Contact the HP
Support center for assistance.
Unexpected hardware I/O configuration4
Ensure the BMC ROM is installed; update BMC
firmware
No Baseboard Management Controller (BMC)
installed in platform
7
Check system logs for errors. Replace the base
unit.
BMC cannot be accessed8
Communication with the BMC failed. Check
power. Replace the base unit.
One or more BMC ports failed9
Clear SELBMC system event log is full10
Contact the HP Support center for assistance.Platform SCR is bad11
Communication with the BMC failed. Replace
the base unit.
Set time to BMC SEL failed12
Communication with the BMC failed. Replace
the base unit.
SEL get info failed13
Communication with the BMC failed. Replace
the base unit.
Initial BMC SEL event failed14
Communication with the BMC failed. Replace
the base unit.
Update of BMC buffered data failed15
Communication with the BMC failed. Replace
the base unit.
All Advanced Configuration and Power Interface
(ACPI) BMC ports bad
16
Communication with the BMC failed. Replace
the base unit.
Read error on BMC token17
Communication with the BMC failed. Replace
the base unit.
BMC token transmit checksum error18
Communication with the BMC failed. Replace
the base unit.
Error writing BMC token on download19
Communication with the BMC failed. Replace
the base unit.
Non-Volatile Memory (NVM) token access error20
Communication with the BMC failed. Replace
the base unit.
BMC token write error during NVM write through21
Communication with the BMC failed. Replace
the base unit.
Error reading BMC token on upload to NVM22
EFI Error and Warning Messages 101