Operations Guide, Fourth Edition - HP Integrity rx1620

Accessing the logs with MP commands
The SEL and FPL data can also be accessed from the MP logs using the MP card SL command.
The vcommand (view mode configuration) determines the format of the display:
hex mode
text mode
keyword mode
Hex Mode Example:
0x5E800A7A00E00FD0 0000000000000003
Text Mode Example:
Log Entry 1: 31 Oct 2003 21:34:17
Alert Level 2: Informational
Keyword: Type-02 0a0700 657152
Cooling unit OK
Logged by: Baseboard Management Controller; Sensor: Cooling Device - Fan 1 (PSU)
Data1: transition to OK
0x203FA2D559020020 FFFF0007110A0300
Log Entry 0: 31 Oct 2003 21:33:21
Alert Level 3: Warning
Keyword: Type-02 0a0701 657153
Cooling unit warning
Logged by: Baseboard Management Controller; Sensor: Cooling Device - Fan 1 (PSU)
Data1: transition to Non-Critical from OK
0x203FA2D521020010 FFFF0107110A0300
Keyword mode example:
13 BMC 2 0x203E5F914A0200E0 FFFF010944080300 Type-02 080901 526593 28 Feb 2003 16:41:46
14 SFW 0 2 0x5680006300E000F0 0000000000000000 BOOT_START 28 Feb 2003 16:41:46
15 BMC 2 0x203E5F914B020110 FFFF027000120300 Type-02 127002 1208322 28 Feb 2003 16:41:47
System Specific Events
OEM SensorType 12, EventType 71
Missing components are determined at the time of a power-on request, cause a failure in the
request, and cause the event to be logged.
Table A-2 Missing Components
Missing ComponentData 3Data 2
Power Pod 0-10x0C-0D
CPU 0-10x20-21
Cooling Unit 10x010x1E
106 Event, Error, and Warning Messages