Operations Guide, Fourth Edition - HP Integrity rx1620

Table A-2 Missing Components (continued)
Missing ComponentData 3Data 2
Cooling Unit 20x010x1E
Cooling Unit 30x030x1E
Chassis Control Event Codes
For BMC rev 1.41+, an SEL event will be logged for each ChassisControl event, whether it’s
generated by an IPMI request, or a sensor event.
Later revisions of MP firmware recognize the triplet (12:70:A3) as ChassisControl.
The EventData fields are:
Data1: 0xA3 (indicating OEM data in Data2 and Data3, and OEM offset 3)
Data2:
[7] 0 = Request generated by a Sensor Event
1 = IPMI request
[6-4] Reserved
[3-0] ChassisControl command
Data3: Sensor Number or IPMI Request Origin
Table A-3 Chassis Control Commands
DescriptionCommand
Hard Power Down0x00
Power Up0x01
Hard Reset0x03
NMI/TOC/INIT0x04
Soft Shutdown and Restart0x0D
Soft Shutdown0x0E
Table A-4 Sensor Numbers
DescriptionSensor Number
Power Button0x04
Wake On LAN0x0E
Cooling Units0x11-13
Power Supply0x40
Voltage Sensors0xCD-D3, 0xD5-D6
Ambient Temperature0xD8
CPU Temperatures0xD9-DA
ACPI0xFA
Table A-5 IPMI Origins
SourceNumber
block transfer (BT)0x00
command line interface (CLI)0x03