Table 3-6 Console Input Devices
Choose:To select:
Acpi(PNP0501,0)/Uart(9600 N81)/VenMsg(Vt100+)Serial A/Serial 1
Acpi(HWP0002,700)/Pci(1|1)/Uart(9600 N81)/VenMsg(Vt100+)MP Serial Console
Select Active Standard Error Devices
Use this option to define the devices that display error messages from the system console.
This menu is identical to Console Output Devices. The hp Integrity rx1620 Server does not support
different configurations for Output and Error console. For correct operation:
When changes are made to either Output or Error console menus, the identical change must
be made in both menus.
When changing serial devices, changes must be made to Output, Input, and Error menus
for proper operation.
Using the System Configuration Menu
The System Configuration Menu (on systems with EFI firmware version 2.0 or higher) includes
the following options:
The Security/Password Menu lets you change the administrator and user passwords
The Advanced System Information Menu displays information about system and component
configuration
Set System Date lets you modify the system date
Set System Time lets you modify the system time
Reset Configuration to Default lets you restore system settings to their original configuration
Help displays additional information about the available options
Exit returns to the EFI startup menu
Security/Password Menu
You can set administrator and user passwords to provide different levels of access to the system
firmware:
Resetting Passwords
If you forget your passwords, they can be reset using an MP command. Follow theses steps.
If your system has an MP card:
Run the MP card bp command to reset the administrator and user passwords (see
Management Processor Command Interface”).
If your system does not have an MP card, you must reset the passwords using a jumper on
the system board:
1. Power down the system and unplug the AC power cord.
2. Place a jumper between pins 7 and 8 on J96 located on the system board near the battery.
Using the Boot Option Maintenance Menu 59