Table 3-8 defines alert (or severity) levels.
Table 3-8 Alert Levels
DefinitionSeverity
Minor forward progress0
Major forward progress1
Informational2
Warning3
Critical5
Fatal7
Security Options
SO: Configure security options and access control (users, passwords, and so on)
This command modifies the security parameters of the MP, which include login time-outs and
allowed password faults.
If configured, when you access the MP via the modem port, the MP hangs up and dials the user
back. This does not work if Modem Presence is set to not always connected with the CA
command.
If the mode is Single, the State is changed todisabledafter the first login.
A disabled user’s login is not accepted.
System Status
SS: Displays the status of the system processors
The SS command displays the status of the system processors and which processor is the monarch.
Firmware Revision Status
SYSREV: Displays the revision status of firmware in the system.
This command displays the revision status of firmware in the system.
Management Processor Command Interface 69