Network Interface Cards (NICs)
all Integrity
servers
The driver for the HP PCI-X multifunctional gigabit server adapter (Broadcom 5706
virtual bus driver) may cause a machine check abort (MCA) during system shutdown.
Issue After installing the HP PCI-X multifunctional Gigabit Ethernet server adapter
(Broadcom 5706 virtual bus driver), a system MCA may occur during system
shutdown.
Workaround The system will perform correctly after restarting.
all Integrity
servers
Warning message about Fiber Gigabit Ethernet disconnect at system power-up
(Event ID 4 or Event ID 27)
Issue At system power-up, you may see a Warning message (with a source of b57nd or
e1000) indicating a disconnect. With the A7073A card, Event ID 4 is specified,
and with the A9899A card, Event ID 27.
Workaround This is not an error, but rather a side-effect of the auto-negotiation process used by
the A7073A and A9899A cards. The cards do connect at the end of that process.
You can verify this by going into the Event Viewer, locating the Warning
message, and seeing the Informational message that follows it, indicating a
successful connection (Information Event ID 11 for the A7073A card;
Information Event ID 32 for the A9899A card).
Partition Manager
Superdome,
rx8620, rx7620
Microsoft Visual C++ Runtime Library error message dialog during system shutdown
Issue During shutdown, systems running Partition Manager may display a dialog on the
GUI console indicating a Visual C++ Runtime error.
Workaround This is a program error in the System Management Homepage that has no
operational impact. No user action is needed.