HP Integrity Servers with Microsoft® Windows Server™ 2003 Management Agents Events Reference Guide Published: September 2007
© Copyright 2007 Hewlett-Packard Development Company, L.P. Legal Notices Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice.
Table of Contents About This Document.........................................................................................................5 Intended Audience.................................................................................................................................5 New and Changed Information in This Edition.....................................................................................5 Document Organization.....................................................................
About This Document This document describes the Windows System Log Event ID number, severity, and description of events generated by the HP Integrity Management Agents software on HP Integrity servers running Microsoft® Windows® Server 2003. The document printing date and part number indicate the document’s current edition. The printing date changes when a new edition is printed. Minor changes may be made at reprint without changing the printing date.
A command name or qualified command phrase. A key sequence. A sequence such as Ctrl+x indicates that you must hold down the key labeled Ctrl while you press another key or mouse button. The contents are optional in command line syntax. If the contents are a list separated by |, you must choose one of the items. The contents are required in command line syntax. If the contents are a list separated by |, you must choose one of the items. The preceding element can be repeated an arbitrary number of times.
1 Management Agents Event Tables Introduction This reference guide describes the Windows System Log Event ID number, severity, and description of events generated by HP Integrity Management Agents software. The Management Agents are a group of services that run continuously in the background on HP Integrity servers and report the status of system components. Each Management Agent has its own unique table(s) in this document.
518 Error Uncorrectable multi-bit ECC error has occurred HPECCMemory - 518 in HPIFP02TRAP.MIB 699 Error Machine Check Initiated SystemFW - 699 in HPIFP02TRAP.MIB 700 Error Generic trap for Critical or Fatal type E0 event from system firmware SystemFW - 700 in HPIFP02TRAP.MIB 704 Warning Voltage insufficient HPEnvironment - 704 in HPIFP02TRAP.MIB 705 Error Voltage reached critical level HPEnvironment - 705 in HPIFP02TRAP.
748 Error OS run-time critical shutdown SystemHW - 748 in HPIFP02TRAP.MIB 749 Warning ACPI state S5 (soft-off, entered by override) SystemHW - 749 in HPIFP02TRAP.MIB 750 Warning Watchdog timer expired (no action) SystemHW - 750 in HPIFP02TRAP.MIB 751 Warning PCI parity error detected SystemHW - 751 in HPIFP02TRAP.MIB 752 Warning Temperature sensor crossed lower non-critical threshold hpTempHighWarning - 752 in HPIFP02TRAP.
5036 Warning CPU failed late selftest hpevtBootCpuLateTestFail - 5036 in HPIFPTRAP.MIB 5037 Warning CPU not enough late test memory hpevtBootCpuLateTestInsufficientMem - 5037 in HPIFPTRAP.MIB 5040 Error Could not allocate memory for EFI image hpevtBootEfiAllocateError - 5040 in HPIFPTRAP.MIB 5041 Error EFI image corrupted hpevtBootEfiImageCorrupt - 5041 in HPIFPTRAP.MIB 5042 Error EFI not in fit table hpevtBootEfiNotInFit - 5042 in HPIFPTRAP.
5070 Error SAL_B not in FIT table hpevtBootNoSalBInFit - 5070 in HPIFPTRAP.MIB 5073 Error NVRAM test fail hpevtBootNvmFail - 5073 in HPIFPTRAP.MIB 5076 Error Interrupt vector out of range hpevtBootOutOfRangeVector - 5076 in HPIFPTRAP.MIB 5077 Error Pal proc error getting pal copy info hpevtBootPalCopyInfoError - 5077 in HPIFPTRAP.MIB 5078 Error Pal proc error copying pal to memory hpevtBootPalCopyPalError - 5078 in HPIFPTRAP.
5108 Error CPU unknown boot error hpevtBootUnknownFailure - 5108 in HPIFPTRAP.MIB 5118 Warning CC errors PAL failure hpevtErrorsPalFailure - 5118 in HPIFPTRAP.MIB 5119 Warning Expected MC vector unregistered hpevtExpMcNotRegistered - 5119 in HPIFPTRAP.MIB 5121 Error INIT initiated hpevtInitInitiated - 5121 in HPIFPTRAP.MIB 5123 Warning Expected I/O host bridge is missing hpevtIoCheckLbaMissingErr - 5123 in HPIFPTRAP.
5148 Warning Found invalid PCIXCAP value hpevtIoUnknownPcixcapVal - 5148 in HPIFPTRAP.MIB 5149 Warning Unsupported rope frequency hpevtIoUnsupRopeFreq - 5149 in HPIFPTRAP.MIB 5150 Warning Unsupported host bridge type hpevtIoUnsupportedLba - 5150 in HPIFPTRAP.MIB 5152 Error Machine Check initiated hpevtMcInitiated - 5152 in HPIFPTRAP.MIB 5155 Error Error in temporary mdt area hpevtMdtConstructAreaBad - 5155 in HPIFPTRAP.
5187 Warning MemoryError Information not cleared hpevtMemErrClearFail - 5187 in HPIFPTRAP.MIB 5189 Warning Couldn't clear memory error logs hpevtMemErrLogFailedToClear - 5189 in HPIFPTRAP.MIB 5190 Warning Memory error clear failed hpevtMemErrorRegClearFailure - 5190 in HPIFPTRAP.MIB 5191 Warning DIMM loading order error: DIMM deallocated hpevtMemExtFatalLoadOrdErr - 5191 in HPIFPTRAP.MIB 5193 Warning Generic memory firmware error hpevtMemFirmwareProb - 5193 in HPIFPTRAP.
5253 Warning Looping on destructive memory tests hpevtMemWarnLoopOnDestTest - 5253 in HPIFPTRAP.MIB 5255 Warning DIMM Set Check has been skipped hpevtMemWarnSetCheckBypass - 5255 in HPIFPTRAP.MIB 5256 Warning Serial Presence Detect (SPD) has been skipped hpevtMemWarnSpdBypass - 5256 in HPIFPTRAP.MIB 5257 Warning An Alternate Memory Config has been loaded into the system hpevtMemWarnUsingAltConfig - 5257 in HPIFPTRAP.
5404 Warning Error in a fabric Port hpevtFabricPortError - 5404 in HPIFPTRAP.MIB 5405 Warning Parity error detected on read from fabric hpevtFabricReadError - 5405 in HPIFPTRAP.MIB 5406 Warning Error writing to Fabric hpevtFabricWriteError - 5406 in HPIFPTRAP.MIB 5407 Error hpevtXbcSlicesHwVersionDiffer - 5407 Crossbar slices are out of rev with each other. in HPIFPTRAP.
5452 Error hpevtIoLbaMiscUncErr - 5452 in Misc. uncorrectable error discovered on LBA. HPIFPTRAP.MIB 5453 Error LBA encountered an uncorrectable parity error. hpevtIoLbaUncParityErr - 5453 in HPIFPTRAP.MIB 5454 Error LBA Misc. FatalError encountered. hpevtIoLbaMiscFatalErr - 5454 in HPIFPTRAP.MIB 5455 Error LBA Fatal function error encountered. hpevtIoLbaFatalFunctionErr - 5455 in HPIFPTRAP.MIB 5456 Error LBA Fatal Parity error encountered. hpevtIoLbaFatalParityErr - 5456 in HPIFPTRAP.
5499 Warning hpevtNvramBlockNotFound - 5499 in The requested NVRAM block was not found. HPIFPTRAP.MIB 5500 Warning The requested NVRAM block is locked. hpevtNvramBlockLocked - 5500 in HPIFPTRAP.MIB 5501 Warning Firmware tried to unlock a NVRAM block that was already unlocked. hpevtNvramBlockUnlocked - 5501 in HPIFPTRAP.MIB 5502 Error The Header in NVRAM was not found hpevtNvramHeaderNotFound - 5502 in HPIFPTRAP.MIB 5503 Error The Freelist used for NVM block allocation is corrupt.
5557 Error The cell monarch cpu has failed. hpevtMcCellMonarchTimeout - 5557 in HPIFPTRAP.MIB 5558 Error This indicates that the cell missed the rendezvous at the partition level. hpevtMcPdCellMissedRendez - 5558 in HPIFPTRAP.MIB 5559 Error This means that the PD monarch timedout. hpevtMcPdMonarchTimeout - 5559 in HPIFPTRAP.MIB 5560 Error SetViewRoot on a remote cell failed. hpevtRemoteSetViewRootError - 5560 in HPIFPTRAP.
5598 Warning Fru Id read error hpevtBootFruReadError - 5598 in HPIFPTRAP.MIB 5599 Warning Fru Id checksum error hpevtBootFruXsumError - 5599 in HPIFPTRAP.MIB 5600 Warning Fru Id version error hpevtBootFruVersionError - 5600 in HPIFPTRAP.MIB 5601 Warning Rom revision not equal to FIT revision hpevtBootRomRevToFitRevWarning 5601 in HPIFPTRAP.MIB 5602 Warning ROM revision not equal to Rev block hpevtBootRomRevToRevBlockWarning - 5602 in HPIFPTRAP.
hpevtMcRendezvousSlavesFail - 5677 in HPIFPTRAP.MIB 5677 Warning MC: Monarch failed in slave rendezvous 5679 Warning MC_RENDEZVOUS: Rendezvous vector out hpevtMcRendezBadVectRange - 5679 in of range HPIFPTRAP.MIB 5682 Warning MC_RENDEZVOUS: No MC monarch 5683 Warning hpevtMcRendezNoWakeup - 5683 in MC_RENDEZVOUS: No wakeup registered HPIFPTRAP.
5722 Warning EFI unable to read current speedy boot settings hpevtEfiSpeedyBootTokenNotRead 5722 in HPIFPTRAP.MIB 5723 Error Unpermitted SAL callback attempted hpevtEfiSalCallbackAttempted - 5723 in HPIFPTRAP.MIB 5724 Warning EFI unable to determine frequency base of the CPU interval timer hpevtEfiSalFreqBaseUnknown - 5724 in HPIFPTRAP.MIB 5725 Warning EFI system events already initialized hpevtEfiSysEventAlreadyInit - 5725 in HPIFPTRAP.
5750 Warning Cannot get system ID status from BMC hpevtEfiSysidBmcWarning - 5750 in HPIFPTRAP.MIB 5751 Warning Cannot read a system ID hpevtEfiSysidBmcReadError - 5751 in HPIFPTRAP.MIB 5752 Warning Failed to write new system ID. BMC reported hpevtEfiSysidBmcWriteError - 5752 in an error HPIFPTRAP.MIB 5753 Warning The system ID(s) currently in the system is invalid hpevtEfiSysidInvalid - 5753 in HPIFPTRAP.
5784 Error EFI unable to initialize internal library hpevtEfiPosseLibNotInit - 5784 in HPIFPTRAP.MIB 5785 Error EFI unable to initialize security system hpevtEfiSecurityNotInit - 5785 in HPIFPTRAP.MIB 5786 Warning EFI detected invalid internal privilege level hpevtEfiSecInvalidSysmode - 5786 in HPIFPTRAP.MIB 5787 Warning EFI detected invalid privilege level when setting password hpevtEfiSecSetPassLevelErr - 5787 in HPIFPTRAP.
5811 Warning Write through to BMC token failed hpevtBootNvmWriteToBmcTokenFailure - 5811 in HPIFPTRAP.MIB 5812 Warning Utilities reported an error while trying to manipulate the LED hpevtUtilitiesLedError - 5812 in HPIFPTRAP.MIB 5813 Error Duplicate Cpu Ids were detected within a cell. hpevtDuplicateCpuIds - 5813 in HPIFPTRAP.MIB 5823 Warning OS crashdump started (D700) hpevtHp-uxCrashdumpStarted - 5823 in HPIFPTRAP.
7658 Error A XBC port route around has occurred hpevtXbcPortRouteAround - 7658 in HPIFPTRAP.MIB 7660 Warning During routing a crossbar is found to be in an unexpected routing state. hpevtXbcUnexpectedState - 7660 in HPIFPTRAP.MIB 7661 Warning An unexpected XBC forward progress state hpevtXbcRoutingStateTimeout - 7661 in was continually found until timing out. HPIFPTRAP.MIB 7663 Error During remote routing, the current port's neighbor is not healthy.
7774 Warning PDHC FW was reset by hardware due to firmware inactivity. hpevtPdhcWatchdogTimedOut - 7774 in HPIFPTRAP.MIB 7781 Warning Power Up Aborted, Over Temp hpevtAbortPowerupOth - 7781 in HPIFPTRAP.MIB 7782 Error Too Few Bulk Power Supplies Available hpevtAbortPwrupBps - 7782 in HPIFPTRAP.MIB 7783 Error No Cabinet Start, Insufficient Blowers hpevtAbortStartBlowr - 7783 in HPIFPTRAP.MIB 7784 Error No Cabinet Start, Insufficient IO Fans hpevtAbortStartIofan - 7784 in HPIFPTRAP.
7846 Error Cabinet Shutdown - Insufficient IO Fans hpevtShutdownIofan - 7846 in HPIFPTRAP.MIB 7849 Warning IO Expansion Utility Cabinet Fan Failed hpevtXucFanFail - 7849 in HPIFPTRAP.MIB 7855 Error Watchdog Timer Expired hpevtCluWatchdogReset - 7855 in HPIFPTRAP.MIB 7856 Error Invalid checksum from EEPROM hpevtEepromInvalidCksm - 7856 in HPIFPTRAP.MIB 7858 Warning System Backplane Power Board Fault hpevtHbpbBoardPowerFault - 7858 in HPIFPTRAP.
7902 Error PDH Controller firmware version is not supported with this version of MP FW hpevtPdhCtrlrFwMismatch - 7902 in HPIFPTRAP.MIB 7903 Error Power fault on cell board hpevtCellPowerFault - 7903 in HPIFPTRAP.MIB 7938 Warning The CPU Node reported a problem initializing its node in the device tree hpevtCpuInitNodeError - 7938 in HPIFPTRAP.MIB 7939 Warning The ExecuteCommand function failed on a CPU. hpevtCpuExecuteCmdError - 7939 in HPIFPTRAP.
8136 Warning An attempt to read from a device on the PDHC's SM bus has failed. hpevtPdhcSmbusReadFailed - 8136 in HPIFPTRAP.MIB 8137 Error Cell boot has been disabled due to a failure setting the frequency registers. hpevtFrequencyProgramFailed - 8137 in HPIFPTRAP.MIB 8138 Warning An error has occurred while updating System hpevtSysFwFlashUpdateError - 8138 in FW. HPIFPTRAP.MIB 8139 Warning The PDHC firmware was reset for some unknown reason.
8200 Warning An unknown error has been detected by the hpevtPmFirmwareUnknownErr - 8200 PDHC firmware. in HPIFPTRAP.MIB 8202 Error Data field contains data meant for firmware hpevtPmCriticalDebug - 8202 in debug only. HPIFPTRAP.MIB 8205 Warning Testing of correctable errors injected from the CC has failed hpevtFabricLinkCorErrTestFailure - 8205 in HPIFPTRAP.MIB 8206 Error A cabinet has been configured using an invalid cabinet number hpevtInvalidCabinetNumber - 8206 in HPIFPTRAP.
8645 Error The attempt to update the PD Addr Map to hpevtBootOlaFailedUpdatePdAddrMap include OLA cell failed. - 8645 in HPIFPTRAP.MIB 8646 Error Attempt to update the PD PDT with OLA Cell failed hpevtBootOlaFailedUpdatePdPdt - 8646 in HPIFPTRAP.MIB 8647 Warning Attempt to update the cell map to include the OLA Cell failed hpevtBootOlaFailedUpdateCellMap 8647 in HPIFPTRAP.
8720 Error There was an error discovering the LBA hpevtIodiscLbaDiscoverError - 8720 in HPIFPTRAP.MIB 8721 Warning There was an error configuring the LBA hpevtIodiscLbaConfigError - 8721 in HPIFPTRAP.MIB 8722 Error There was an error scanning the PCI bus hpevtIodiscLbaPciscanError - 8722 in HPIFPTRAP.MIB 8723 Error There was an error configuring PCI space through the LBA hpevtIodiscLbaPciconfigError - 8723 in HPIFPTRAP.
8818 Warning The bulk specified is warning of a potential thermal problem. hpevtBpsWarnOt - 8818 in HPIFPTRAP.MIB 8819 Error Malloc failed while trying to process and ERM hpevtErmOutOfHeap - 8819 in HPIFPTRAP.MIB 8821 Warning Dimm at physical location in data field is not hpevtMemDimmUnsupported - 8821 in supported on this platform. HPIFPTRAP.MIB 8828 Error The OPTIONS component received a memory allocation error. hpevtOptsMallocError - 8828 in HPIFPTRAP.
8883 Warning hpevtOptsBlockCksumError - 8883 in Option block in nvram has a checksum error HPIFPTRAP.MIB 8894 Warning CC to CC link did not initialize on the local cell hpevtFabricColaLocalCcLinkNotInit 8894 in HPIFPTRAP.MIB 8895 Warning Failed to write the CC link disable register hpevtFabricXinInitDisableWrError - 8895 in HPIFPTRAP.MIB 8896 Warning An unknown backplane type was found hpevtFabricXinErrMaskUnknownBkp 8896 in HPIFPTRAP.
8968 Warning Error checking a cell to cell link during traversability tests hpevtFabricRouteTraversableCc2CcErr - 8968 in HPIFPTRAP.MIB 8969 Warning An error occurred while traversing the cell to cell link. hpevtFabricDataRouteTraversableCc2CcErr - 8969 in HPIFPTRAP.MIB 8970 Warning Error reading the local cell's XIN link state hpevtFabricCc2ccTraverseLclXinRdErr - 8970 in HPIFPTRAP.
9043 Warning A reset for reconfiguration will be performed hpevtReconfigResetScheduled - 9043 in soon on the cell. HPIFPTRAP.MIB 9045 Warning The Partition Profile specifies the wrong architecture type hpevtProfileWrongArchType - 9045 in HPIFPTRAP.MIB 9046 Warning Cell/Partition is about to be reset because PDC is unable to access CPU data hpevtBootCheckCpuIsDeconfigErr - 9046 in HPIFPTRAP.
9389 Error PDH space not available after release from reset. hpevtPdhcPdhNotAvailable - 9389 in HPIFPTRAP.MIB 9390 Error MPON failed to release. hpevtPdhcMponFailed - 9390 in HPIFPTRAP.MIB 9391 Error Dillon failed to reset. hpevtPdhcDillonResetFailed - 9391 in HPIFPTRAP.MIB 9392 Error DMD clock is not running. hpevtPdhcDmdClockFailed - 9392 in HPIFPTRAP.MIB 9394 Error All cpus on the Cell are scheduled to be deconfigured hpevtAllCpusDeconfOnCell - 9394 in HPIFPTRAP.
9461 Warning A failure has occurred trying to get the number of CPU cores per module. hpevtBootGetNumcoresFailure - 9461 in HPIFPTRAP.MIB 9465 Warning Couldn't read the topology from the XBC register hpevtFabricRmtRoutePortTopoErr - 9465 in HPIFPTRAP.MIB 9466 Error Attempt to update Cell Static Routing has failed hpevtFabricCellRerouteFailure - 9466 in HPIFPTRAP.
9491 Error Error initializing structured I/O exception data structures. hpevtIoDiscEeInitializationErr - 9491 in HPIFPTRAP.MIB 9492 Error The I/O exception context has an error. hpevtIoDiscEeContextErr - 9492 in HPIFPTRAP.MIB 9493 Error Error creating the internal data and services hpevtIoDiscCreateSbaNodeErr - 9493 in for the SBA. HPIFPTRAP.MIB 9494 Error Error attaching the services to the SBA internal data structures. hpevtIoDiscSbaAttachserviceErr - 9494 in HPIFPTRAP.
9697 Error PDC failed reading a specific value from its own copy of the RDRs hpevtBootReadPrefetchFailed - 9697 in HPIFPTRAP.MIB 9698 Error PDC failed reading a specific value from its own copy of the RDRs hpevtBootReadZlcoFailed - 9698 in HPIFPTRAP.MIB 9700 Error PDC failed attempting to update ZLCO and hpevtBootUpdateZlcoAndPrefetchFailed PREFETCH RDR settings - 9700 in HPIFPTRAP.
9768 Error error reading bmc first boot token hpevtBootErrorReadingFirstBootToken - 9768 in HPIFPTRAP.MIB 9769 Warning a rendezvousing cell is non PA architecture and thus incompatible. hpevtBootNonPaCellDetected - 9769 in HPIFPTRAP.MIB 9774 Warning hpevtFabricErrorsXbcClearWrErr - 9774 failed to write the XBC error log clear register in HPIFPTRAP.MIB 9775 Warning Error encountered while reading the XBC CSRError Status Register hpevtFabricErrorsXbcClearRdGlblErr 9775 in HPIFPTRAP.
9870 Warning CPU deconfigured during initialization process hpevtDcnfgCpuDcache - 9870 in HPIFPTRAP.MIB 9871 Warning CPU deconfigured during dcache init hpevtDcnfgCpuCacheState - 9871 in HPIFPTRAP.MIB 9872 Warning CPU deconfigured due to internal error hpevtDcnfgCpuCacheMonitor - 9872 in HPIFPTRAP.MIB 9873 Warning CPU deconfigured due to machine check hpevtDcnfgCpuMca - 9873 in HPIFPTRAP.
10104 Warning The specified system backplane vrm is reporting a temperature fault. hpevtBkPlaneVrmTempFlt - 10104 in HPIFPTRAP.MIB 10105 Warning The specified system backplane rail is reporting a fault hpevtBkPlaneFlt - 10105 in HPIFPTRAP.MIB 10115 Warning Master MP failure. Slave MP has taken control hpevtMstrMpFailed - 10115 in HPIFPTRAP.MIB 10116 Error The NVRAM service was unable to satisfy an NVRAM allocation request hpevtNvramAlloc - 10116 in HPIFPTRAP.
Warning An XBC was found to have an unexpected neighbor port connection. Data field: (expected port) | (actual port 16) | (xbcNum hpevtXBCHaveUnexpctNghbrPrtConn 32) | (portNum 48) - 10380 in HPIFPTRAP.MIB 10381 Warning The expected data was not found in the Arches Fabric expected edge list. Data field is unused. hpevtDataNotFndEdgLst - 10381 in HPIFPTRAP.MIB 10382 Warning An XBC port has an unexpected neighbor chip type. Data field: neighbor type found.
Warning A cell/port pair was not found in the expected graph data. Data field: (cellNum 32) | CC portNum. hpevtCelPrtPairNotFndGrphDat - 10401 in HPIFPTRAP.MIB Warning Arches Fabric Traversability code unexpectedly found the local cell link not connected. Data field: linkState (0 = connected, 1 = link pending, 2 = not connected, -1 = error) hpevtArchFabFndLocCelLnkNotConn 10402 in HPIFPTRAP.MIB Warning Error reading the ROUTEx CSR on the XBC.
Warning Unable to setup the Coherent route table for a cell in our partition. Data field: (sourceCell hpevtUnableSetCohRoutCel - 10432 in 32) | (cell set passed in to SetupCohTable). HPIFPTRAP.MIB Warning Error writing the XBC ROUTE_TABLE_ENABLE_MASK CSR. Data field: (route set to disable) | (xbcNum 32) | hpevtErrWrtXbcRoutTblEnblMskCsr (xbc port 48). 10435 in HPIFPTRAP.MIB Warning The Arches Fabric vertex module returned an unexpected error during Non-Coherent table setup.
10528 Warning Failed to read the XBC Global Semaphore hpevtFailRdXbcGlobSemphr - 10528 in HPIFPTRAP.MIB 10529 Warning Failed to get the address of the XBC Global Semaphore. hpevtFailGetAddrXbcGlobSemphr 10529 in HPIFPTRAP.MIB 10530 Warning Failed to write the XBC Global Semaphore. hpevtFailWrtXbcGlobSemphrAfrRls 10530 in HPIFPTRAP.MIB 10532 Warning hpevtFailRelXbcGlobSemphr - 10532 in Failed to release the XBC Global Semaphore. HPIFPTRAP.
Warning VM_DeleteEdge() failed in the Arches Fabric function SynchGraphs(). Data field:(vertex id1 32) | (vertex port1 48) | (vertex type1 56) | (vertex id2 0) | (vertex port2 16) | (vertex hpevtVmEdgFailFncSyncGrph - 10620 type2 24). in HPIFPTRAP.MIB Warning Unexpected error when calling an Arches Fabric vertex module function. Data field: return value from vertex module function. 10622 Warning Unexpected return from an Arches Fabric vertex module function while copying a cell's graph.
Warning Firmware has run out of NVRAM and cannot hpevtFWOutOfNvram - 10771 in create the needed variable(s) HPIFPTRAP.MIB 10772 Warning The call to the IOC firmware component method "LbaReconfig" failed, probably a low-level hardware error. The fPar BSP is identified in bits 63..32 of the event detail, the fPar owning this CPU and LBA is identified in bits 31..16.
Warning Unable to write to an XBC port ROUTE_TABLE_ENABLE_MASK CSR in Arches Fabric Phase3. Data field: (XBC port hpevtUnablWrtXbcPrtRoutTblEnblMsk 48) | (XBC ID 32) | (route). - 10842 in HPIFPTRAP.MIB 10853 Error An unrecoverable processor interrupt occurred. IPF firmware owned the processor interrupt vector table (IVT) at the time of the hpevtProcessIntrptUnRecoverble - 10853 interrupt. in HPIFPTRAP.MIB 10871 Error hpevtSBASetDevMaskFail - 10871 in SBA call to LBA SetDeviceMask method fails.
Warning An error was encountered while routing the fabric. This error prevents an appropriate hpevtEncntErrRoutFab - 11039 in route from being selected. HPIFPTRAP.MIB 11040 Warning An error was encountered while routing the fabric. This error prevents an appropriate hpevtErrEncntRoutFabPrvntRoutSel route from being selected. 11040 in HPIFPTRAP.MIB 11041 Warning An invalid port number was returned when hpevtInvlPrtRetRoutXbcCcLnk - 11041 selecting a route for the XBC-CC link. in HPIFPTRAP.
11481 Warning System backplane Hot Swap Oscillator (HSO) hpevtHsoNoRedund - 11481 in boards are NOT redundant. HPIFPTRAP.MIB 11482 Error System backplane Hot Swap Oscillator (HSO) hpevtHsoInsuff - 11482 in boards are insufficient. HPIFPTRAP.MIB Warning Failure reading Redundant Clock Source (RCS) or Hot Swap Oscillator HSO boards EEPROM. hpevtFailRdRcsHso - 11483 in HPIFPTRAP.MIB 11484 Error Failure writing Redundant Clock Source (RCS) or Hot Swap Oscillator HSO boards EEPROM.
11566 Error IO Backplane 3.3V power fault hpevtIOBckPln33VFail - 11566 in HPIFPTRAP.MIB 11567 Error IO Backplane 5.0V power fault hpevtBckPln5VFail - 11567 in HPIFPTRAP.MIB 11568 Error IO Backplane -12V power fault hpevtIOBckPlnNeg12VFail - 11568 in HPIFPTRAP.MIB 11569 Error IO Backplane +12V power fault hpevtIOBckPln12VFail - 11569 in HPIFPTRAP.MIB 11575 Error IO Backplane 1.5V temperature fault hpevtIOBckPln15VTempFail - 11575 in HPIFPTRAP.MIB 11576 Error IO Backplane 3.
Error Memory locking failed. The data is the size of the memory block which could not be locked Error The minimum number of processors required is more than the number available. The data hpevtMinProcReqMoreThanAvail is the number of available processors 11605 in HPIFPTRAP.MIB 11607 Error The guest operating system performed an operation which could not be handled by the virtual machine. The virtual machine could hpevtVMNotHandlGuestOSPerf - 11607 not continue running the guest so it stopped.
Error hpevtVMRebootFail - 11724 in Reboot failed. The virtual machine will exit. HPIFPTRAP.MIB 11775 Warning SetupInitialCohTables() returned an error. Data field: (cell set 32) | (return value from SetupInitialCohTables()). hpevtSetIntlCohTblRetErr - 11775 in HPIFPTRAP.MIB 11780 Warning Stable store read or write to flash failed. hpBootStblStoreFlashErr - 11780 in HPIFPTRAP.MIB 11783 Warning Error reading or writing the stable store NVM area hpBootStblStoreNvMErr - 11783 in HPIFPTRAP.
11961 Warning The System Firmware call to PAL_COPY_PAL failed. hpevtSysFWCallPalCopyPalFail - 11961 in HPIFPTRAP.MIB 11962 Warning The System Firmware call to PAL_CACHE_FLUSH failed. hpevtSysFWCallPalCacFlusFail - 11962 in HPIFPTRAP.MIB 11964 Error Cell on line add/delete is not initialized hpevtCellNotInit - 11964 in HPIFPTRAP.MIB 11966 Error An FPARs component on which cell on-line hpevtFPARsCompBroke - 11966 in add/delete depends is broken or missing. HPIFPTRAP.
12050 Error A CPU module's temperature has exceed the high temperature threshold or a CPU power module fault has occurred. As a result of this event, the CPU has been inhibited. The Cell must be powered off then on using the MP's hpevtCpuTempExceedHiThres - 12050 PE command to clear. in HPIFPTRAP.MIB 12069 Warning SFW detected an error while writing to stable hpevtSFWDetErrStablStorFlsh - 12069 in store flash. HPIFPTRAP.
12150 Error An unrecoverable processor interrupt occurred while in IPF firmware. The event data is the processor ISR. 12153 Warning Double chip sparing has been invoked 12155 Error External clock cable has been removed from the CPU cabinet. The data field contains the hpevtExtClkCablRemvFrmCPUCab physical location of the cabinet. 12155 in HPIFPTRAP.MIB 12156 Warning System Fabric encountered a link error after hpevtSysFabEncntLnkErr - 12156 in opening up the fabric link. HPIFPTRAP.
12210 Warning The operating system set the watchdog timer to time out if it was not reset within a specified time. It was not reset and has timed out. The management processor will now take the action specified when the timer was hpevtOSSetWtchDogTimerToTimeOut set. - 12210 in HPIFPTRAP.MIB 12217 Error An OS is shutting down due to an MCA (Machine Check Abort) or INIT. hpevtOSShtDwnDueMCA - 12217 in HPIFPTRAP.MIB 12218 Error An OS is shutting down due to a panic.
Error The alternate ROM failed to authenticate. The current (primary) ROM will continue to be hpevtROMFailAuthentc - 12352 in used HPIFPTRAP.MIB 12354 Error The alternate ROM was successfully authenticated but the primary and alternate ROM could not be swapped. The current hpevtAltrntROMUnblSwap - 12354 in primary will still be used. HPIFPTRAP.
12557 Warning HP unsupported DIMM(s) has been detected hpevtUnSupprtDimmInPartition - 12557 on this partition. in HPIFPTRAP.MIB 12560 Error OS run-time critical shutdown occurred. hpevtRuntimeCritShtDwn - 12560 in HPIFPTRAP.MIB Platform Events – Table 2 (Windows System Log Event ID, Cause, Recommended Action) 62 Event ID What Might Be Causing This Event? 4 The temperature inside the server has gone outside the factory specified range for normal operation.
12 The voltage in the server has gone far outside the factory set range and could damage system components. A bad component, blown fuse, poorly seated module, loose cable, or debris could Check all boards, power supplies, and modules be responsible for this failure. that either supply or use this voltage rail. 26 The server has detect that the chassis door or other access panel is not securely closed. Close any open panels or chassis doors. 76 One of the server's drives has been removed.
707 There is either a missing or failed power component. This may be a normal message when a system is not loaded to capacity and power If this is unexpected, then check all boards, power components are purposefully left out of the supplies, and modules that either supply or use system. this voltage rail. 710 Possibly, the specified fan is beginning to lose performance. If these errors continue to be reported, the fan should be replaced.
739 A required device was not detected. See the System Log (SEL). Install missing, required device. 740 A required device was not detected. Install missing, required device. 744 The System Log is almost full. Review the log for any important events, then clear it. 745 The critical interrupt sensor has detected that there was a Diagnostic Interrupt initiated by IPMI command.
753 The temperature inside the server has gone far outside the factory specified range for normal operation. To avoid permanent damage to your server hardware, go and turn off the server immediately.
5010 The system has failed to launch EFI because of an internal error. Reboot or update System FW. If problem persists contact your HP representative for support. 5011 An internal error has caused monarch selection to fail. Reboot. If problem persists contact your HP representative for support. 5013 Unexpected error has occurred during monarch Reboot, if problem persists contact your HP selection. representative for support.
5053 FPL access has failed, possibly due to BMC Reboot or update System and BMC FW. If communication interruption. SFW will not send problem persists contact your HP representative any events to the FPL until the system is rebooted. for support. 5054 SFW tried to read the Processor Status Register before the CPU data structure has been setup. Reboot, if problem persists contact your HP representative for support. 5055 InternalError contact your HP representative for support.
5091 No wakeup vector registered for processor. Reboot, if problem persists contact your HP representative for support. 5092 SFW is unable to determine the FSB speed. Reboot, if problem persists contact your HP representative for support. 5098 SFW failed to build the SMBIOS tables. If SMBIOS is preventing functionality, reboot. If problem persists contact your HP representative for support. 5100 The trap nesting limit has been exceeded.
Contact your HP representative to check the firmware. 5132 Internal firmware error. 5133 A failed or improperly seated I/O card is present. Replace or reseat the I/O card(s). 5136 I/O CEC failure. 5137 The IO config in the system is unsupported. Verify that the IO config installed in the system The power budget for the IO subsystem has been is one that is supported. If problem persists exceeded. contact your HP representative for support. 5138 Internal firmware error.
5159 TheError handler has failed to retrieve or log data Reboot if necessary, if problem persists contact due to a media failure. your HP representative for support. 5160 The CEC failed the register test. Contact HP support to troubleshoot the problem.
5205 Internal SFW error. Update to most recent SFW. 5208 No DIMMs were detected Install DIMMs or Contact HP Support personnel to troubleshoot the problem 5209 FW found memory, but it could not find a correctly loaded rank. Before this event is sent, FW will output which ranks it is deallocating and why. Review the preceding events and refer to the users manual to correct the memory loading.
5266 A PDH register has failed. Reboot if necessary, if problem persists contact your HP representative for support. 5268 The handler for SAL_CHECK has failed for an unknown reason. Reboot if necessary, if problem persists contact your HP representative for support. 5270 The handler for SAL_INIT has failed for an unknown reason. Reboot if necessary, if problem persists contact your HP representative for support. 5278 FW encountered a fatal interleaving error. Update SFW.
5417 ROM is corrupt. Replace the rom or reprogram flash. 5418 Verify all connections of PDH bus components or replace the cell board. 5419 A PCI card is configured with mixed speeds. Correct the configuration problem. 5420 Too many PCI bridge cards are configured in single PCI segment mode. Reconfigure PCI cards and remove some of the bridge devices. 5432 Hardware problem such as cable connect error or bad cables. Correct the hardware problem and re-boot.
5485 Reset 5490 Determine the failing component or hardware from the data field as described and replace. 5491 Report the IP to the firmware team. Reset the system. This cannot be worked around in the field. 5492 Bad NVRam, replace the bad chip. 5493 Firmware/software error 5494 Decode the hex vales to ASCII to determine the mode. Other errors will determine action. Check for new version of firmware/OS Contact HP Support Reset system to clear the semaphore Try reinitializing NVRAM.
5525 Memory test code located in main memory has been corrupted 5527 Reset the PD. 5528 Verify that the complex profile is correct and reset the partition. 5529 Verify the utilities system is connected correctly and reset. 5530 Make sure the GSP is connected and reset. 5546 When this happens the cell will step through some of the error logging code on its own and then reset itself.
5579 Report the IPF to the firmware team. Reset the system. This cannot be worked around in the field. 5580 Push out consistent Complex profiles and reset the system. The cell will be waiting for reconfiguration. 5581 Reconfigure the partition number, push out a new profile and reset. 5583 No action required 5584 No action required. 5594 Problem accessing the BMC. AC power cycle or update BMC and System FW. If problem persists contact your HP representative for support.
5619 See earlier error event. 5621 Utilities may be unavailable to update the profiles. Check the connections are reset. 5622 Run parmgr to configure the cell into a PD and reset the PD or add the cell. 5623 Rearrange the DIMMs to follow the loading order The current DIMM loading order does not follow specified in the Maintenance and Operation the guidelines in the user manual Manual 5626 PD Rendezvous Boot Rules: If greater than 50% of the assigned cells are rendezvoused, we will boot.
5686 PAL does not support call to set the processor feature set during processor rendezvous update system firmware with new PAL that support the PAL_SET_FEATURE call. 5692 Report the IP to the firmware team. Reset the system. This cannot be worked around in the field. 5696 The memory extenders have not been loaded in Load the Memory extenders according to the the correct order. users manual. 5698 New table entry types added by SAL not understood by EFI. Upgrade system firmware.
5728 Unable to properly initialize a system firmware node Check for other errors in the system first. Invalidate NVM and retry to boot. Get the latest firmware release. 5729 This is likely to be a symptom of an earlier problem, or the system is out of malloc space. Contact system firmware team. 5730 This is usually a symptom of an earlier problem. Check to be sure the pdh node was initialized into the tree correctly. 5731 This is usually due to a memory allocation problem.
5752 Check content of FRU EEPROM of the system board and secondary location using ifru. If FRU EEPROM content can be accessed on both board flash BMC firmware. If content cannot be accessed on system board replace system board. If content cannot be accessed from the secondary location, replace the secondary location FRU. If it cannot Inaccessible/corrupted FRU EEPROM on system be done or doesn't solve the issue replace system board and/or I/O backplane. board.
5779 The user installed a mismatched pair of DIMMs in the same rank (i.e. the DIMMs are different Install memory ranks in pairs of DIMMs that are size or DRAM width). the same size and DRAM width. 5784 Internal EFI error. Reboot. If problem persists contact your HP representative for support. 5785 BMC not responding properly. Reset BMC. Contact your HP representative if problem persists. 5786 SAL storage corrupted. Reboot system. 5787 Internal EFI error. Upgrade system firmware.
5812 It is likely the GSP is not present or the device specified is not present. Solve these problems and try again. 5813 Most likely cause is a bad cpu module connection on the cell board. Replace the cell board. 5823 panic occurred 5824 fault/panic 5825 panic, mca, or INIT path: attempt to write out the dump is complete No action required 5827 A PAL call made by SFW has failed. Reboot if necessary, if problem persists contact your HP representative for support. 5832 BMC failed.
7658 An XBC is indicating a port failure Validate all of the cells connectivity to the PD Check the XBC chips seating reset the system replace either cells/system backplane 7661 An XBC is indicating a port failure Validate all of the cells connectivity to the PD Check the XBC chips seating reset the system replace either cells/system backplane 7663 An XBC port is not healthy. Check for hardware failure: flex cables, crossbar chips, etc. 7664 The CC to XBC link is not operational.
7690 Either the ROM was programmed incorrectly or has gone bad. Reprogram the Flash on the cell board. 7718 This is an alien IO backplane. IO discovery will fail. I/O for the cell will not be initialized. 7732 2 cpus are at different revisions. Replace incompatible cpu. 7733 There is a CPU or Cell compatibility problem. Verify that all cpus are clocked at the same frequency and have the same ratios set. 7734 A cpu is being clocked at a rate higher than it is rated for.
7782 Remove entities until Power Requirements are Too many entities installed in the cabinet for the met. Add Bulk Power Supplies, if under Power Available. populated. 7783 The number of blowers required is a hard number. It is not dependent upon the number of entities installed in a Cabinet. The Utilities Subsystem is not allowing the Cabinet to power Install missing Cabinet Blowers. If proper number up due to an insufficient number of installed of blowers are installed, troubleshoot blower blowers.
Room Temperature is rising or falling. Check the error log's previous entries within a logical time frame. If temperature is rising, prepare for system shutdown. If temperature is dropping, then problem is probably resolved. Room Temperature is rising or falling. Check the error log's previous entries within a logical time frame. If temperature is rising, prepare for system shutdown. If temperature is dropping, then problem is probably resolved.
Input power has created some fault conditions. This will be evident by the presence of several chassis codes in theError Log within the same time frame. TheError Log must be reviewed carefully for the root cause of the errors. There is almost always a single cause, even if many events are reported. 7871 The MP is not communicating with the CLU. The MP bus (USB) is not functioning. There should be many entries in theError Log with the same type of error message. They will point to MP bus errors.
7893 The CPU fan identified by the attached physical Contact HP Support personnel to troubleshoot location is not operating at expected speed. problem 7894 The CC chip fan identified by the attached physical location has failed. Contact HP Support personnel to troubleshoot problem 7895 The CC chip fan identified by the attached physical location is not operating at expected speed.
8010 Contact Engineering, This is a bug. 8127 Debug event. 8128 Check revision of CLU firmware. If out of date, CLU firmware on the UGUY has gotten into an or known bad revision, use FWUU to update CLU unexpected execution path, most likely due to a firmware. Contact HP Support personnel to hardware issue on the UGUY. troubleshoot problem 8130 A user has manually, using back-door debugging methods, altered the voltage margin setting of one or more Cell Board or Cell Power Board converters.
8151 A hardware fault is preventing the PDH bus semaphore from being taken/released as expected. Contact HP support personnel to troubleshoot the Cell Board and/or PDH Daughtercard 8153 An unknown OS IPMI driver or Manageability FW bug has occurred. Update PDHC FW, MP FW, System FW and the OS IPMI driver to the latest revisions. 8154 SAL service to read tokens not functioning properly. Reset the system. Clear SFW NVM. Upgrade system firmware.
8214 A hardware error has occurred. 8216 This should not happen. Contact engineering to diagnose the problem. 8218 A CPU on the slave cell could not process an interrupt in time or establish the diva console. 8219 There could be a PD rendezvous error or a processor on the slave cell failed to respond to an interrupt in time. 8220 Push out a new Group C complex profile. 8238 This will lead to a system reset. 8239 An unanticipated error occurred.
8646 Unable to add OLA cell's PDT to the partition PDT.Error accessing PDH space. Check fabric connection between OLA cell and core cell. Gather IPMI event logs and contact HP Support. 8647 Unable to write registers on the CC. Check cell board and system fabric. Collect IPMI events and contact HP Support. 8648 CC to XBC link init failure. check CC, XBC, reset cell, reset backplane 8652 Report the IP to the firmware team. Reset the system. This cannot be worked around in the field.
8721 Unable to configure the LBA replace I/O backplane 8722 Could not scan the card in a populated slot. Typically caused by an improperly installed or faulty PCI card. Reseat or replace the faulty card. 8723 Unable to obtain semaphore reset Update to latest recipe 8745 System firmware was unable to lock either the global or the micro semaphore. Allow the OLA cell to reboot to BIB, then try the OLA operation again. Or, collect IPMI event logs and contact HP Customer Support for assistance.
8814 This can occur if the OS has not returned all the CPUs to firmware or if a cell is not marked correctly in the complex profile to allow its deletion. 8817 N/A 8818 The bulk power supply is warning of an over temperature condition 8819 Heap space is completely used or corrupt. Contact Product Engineering. 8821 Unsupported dimm in specified slot 8828 Invalidate NVRAM and reset. 8837 A deconfigured dimm or cpu has been detected. Examine earlier events to isolate the problem.
8882 Specify a valid parameter. 8883 Clear NVRAM. 8894 link failure between the XBC and the CC Check CC. 8895 Fabric Access Failure. Contact HP Support personnel to analyze the fabric. 8896 CSR Read/Write error Contact HP Support personnel to analyze the fabric. 8897 Fabric AccessError. Contact HP Support personnel to analyze the fabric. 8898 CC CSR access failure. Contact HP Support personnel to analyze the fabric. 8900 CC CSR Access Failure.
8966 Fabric AccessError. Couldn't write this XBC. Contact HP Support personnel to analyze the fabric. 8968 Probably an error reading the XIN. Look for additional descriptive chassis codes. Contact HP Support personnel to check the CC 8969 Probably an error reading the XIN. Look for additional descriptive chassis codes. Contact HP Support personnel to check the CC 8970 Hardware AccessError. Have your HP support representative check the Coherency Controller (CC). 8971 Hardware AccessError.
9022 FirmwareError. 9038 Cell hardware problem like PDH memory itself, the coherency controller, the executing CPU or Contact HP Support to troubleshoot the cell and interaction between any of these cell components. either fix it or replace it. 9039 Cell hardware problem like PDH memory itself, the CC chip, the executing CPU or interaction Troubleshoot the cell and either fix it or replace between any of these cell components. it.
9371 PDC bug. Contact HP Support to check for PDC upgrade. 9372 Hardware connecting cells in the partition experienced a problem such that cells in the partition together can no longer communicate. Troubleshoot the fabric and replace backplane or cells. Gather event logs and contact HP Customer Support for assistance. 9373 Hardware problem with the CPU chip, CC chip, Troubleshoot the cell and/or replace it. Contact or PDH flash. HP Customer Support for assistance.
9419 A power source has been removed from the chassis. 9420 A power source has been removed from the chassis. 9428 Have your HP Support Representative check the Coherency Controller 9430 XBC access failure. Check XBC, check links, check backplane, check CC. 9431 CC access failure. Contact HP Support personnel to check the CC. 9432 CC access failure. PDC Reviewed alert level for SR - 9/6/03 CC. 9433 fabric access failure Check XBC, Check CC, Check backplane 9438 PDH battery power is low.
Fabric Access Failure Contact HP Support personnel to check the XBC, Backplane, CC, look for additional chassis codes to describe the problem. Fabric Access Failure Contact HP Support personnel to check the XBC, Backplane, CC, look for additional chassis codes to describe the problem. Fabric Access Failure Contact HP Support personnel to check the XBC, Backplane, CC, look for additional chassis codes to describe the problem.
9495 This is a system firmware error. Reset the partition; invalidate NVM on the reporting cell and reset the partition; or check for newer system firmware. 9496 This is either a system firmware error, or the wrong I/O is connected to the system. Validate the system recipe both firmware and hardware. 9497 Replaces the I/O card specified by the physical location. 9498 2 or more XBC links are not routable.
9685 NVRAM has become corrupt. Restore from a backup. 9695 Hardware problem with the CPU. Contact HP Support to confirm the CPU is functioning properly. 9696 Hardware problem with the CPU. Contact HP Support to confirm the CPU is functioning properly. 9697 Problem on cell wherein PDC could not properly access memory Contact HP support to troubleshoot cell board 9698 a non-existent/non-accessible register was specified by software.
9742 Cells exist in both cabinets, but one of the cabinets has no cells powered on. If a 2 cabinet configuration is desired, shutdown any active partitions and power off both cabinets and then power them both on, including at least 1 cell in each cabinet. (Note: it is possible to get this event ID and have both cabinets powered on. In this event, no action is required.) 9744 An error occurred while collecting the PCI error No action can be taken.
9775 Fabric Access Failure. Likely hardware problem. Look for additional chassis codes to further isolate the error. 9776 This could be caused by a fabric access error or persistent CSR Low Severity errors. Check Crossbar hardware, flex cables, backplane 9777 This could be caused by a fabric access error or persistent CSR Low Severity errors. Check Crossbar hardware, flex cables, backplane 9778 Fabric Access Failure. Likely hardware problem.
internal error. during system boot the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support. 9870 internal error. during system boot the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support. 9871 internal error. the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support. 9872 internal error. the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support.
10104 10105 10115 10116 NVRAM is full. This is extremely unlikely. Clear NVRAM and reset. 10132 Bad RTC chip on the PDH daughtercard. Replace PDH daughtercard 10159 An uncorrectable PAA fault has occurred on the MX2 module and PAA firmware has halted. Contact your HP support personnel. 10209 An error prevented the use of a fabric link. Collect IPMI event logs for more information regarding the failure. Contact your HP Support Representative to investigate the fabric subsystem.
10381 Capture IPMI event logs, look for additional errors. Contact your HP Support Representative Internal system firmware error or data corruption. to analyze the fabric 10382 System firmware found an unexpected chip in the system. 10384 Capture IPMI event logs, look for additional A link that was previously healthy was found to errors. Contact your HP Support Representative be down. to analyze the fabric 10385 A link was found to have fatal errors, possible bad link/connection.
10402 Capture IPMI event logs, look for additional A previously healthy link was found to have fatal errors. Contact your HP Support Representative errors. to analyze the fabric 10403 System firmware was unable to read a fabric hardware register. Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric 10404 System firmware was unable to read a fabric hardware register. Capture IPMI event logs, look for additional errors.
10439 System firmware was unable to write a fabric hardware register. Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric 10475 System firmware was unable to write a fabric hardware register. Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric 10481 SFW was unable to access the configured set stored in the complex profile.
Look for additional IPMI event logs. Contact your HP Support Representative to analyze the fabric. 10558 Failed to get a fabric address 10559 System Firmware was unable to open the crossbar Collect IPMI Logs. Contact your HP Support link Representative to analyze the fabric. 10560 write to XBC failed Contact HP Support personnel to check the XBC 10561 write to XBC failed Contact HP Support personnel to check the XBC 10564 System Firmware was unable to route the crossbar fabric.
10628 Both SAL's copy and BMC copy of the token specified in the data field is bad. SFW is reinitializing that token to it's default value Verify that the default settings are appropriate. For example, run the EFI baud and boot test command. 10629 Incorrect I/O backplane and/or I/O backplane cables are connected to the cell board. The cell board is not compatible with I/O backplane and/or I/O backplane cables.
10823 Threshold parity errors have been detected in the Instruction or Data Cache Memory (I-Cache or D-Cache). The operating system has recovered from the errors, but this is an abnormally high Contact your HP support representative to check failure rate the processor 10824 Threshold corrected platform errors have been detected in the cache portion of the memory for the processor module.
10936 Reconfigure the soft partition containing the CPU that emitted this event and be sure to give memory resources to that soft partition before reset of that partition. Until doing so, this soft There is no Memory owned by the soft partition partition will be unbootable and emit this event (fPar) whose CPU emitted this event. on each attempt. 10937 There was a problem while collecting a list of fabric link info. Look for additional IPMI event logs.
11456 System backplane power board has reported a 3.3v house keeping fault. Check system backplane power board. 11459 System backplane power board has reported a 12v fault. Check system backplane power board. 11461 System backplane power board has reported a 3.3v fault. Check system backplane power board. 11463 System backplane power board has reported a 1.5v fault. Check system backplane power board. 11465 System backplane power board has reported a 2.5v fault.
11530 The user has configured an fPar to be booted with inadequate memory resources to instantiate the firmware image for this fPar. The fPar is software deconfigured (disabled) from booting. 11531 The fPar has been enabled to boot, and contains at least one CPU and adequate memory but has not been given any IO resources. The soft partition (fPar) may therefore only boot as far as Reconfigure the soft partition using an the EFI shell.
An error occurred while routing the fabric. Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. An error occurred while routing the fabric. Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. An error occurred while routing the fabric. Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware.
11719 This is an internal error. If this continues to occur, reinstall the software. If this does not fix the problem contact your HP support representative. 11720 The configuration file is missing or damaged. Restore the configuration from a backup or recreate the guest. 11721 Insufficient memory available Increase available memory or swap file space 11723 Insufficient resources or PMAN kernel memory too fragmented Add memory or reboot 11724 The virtual machine was unable to restart.
32 OS or firmware bugs Call HP support 11933 Software data corruption Call HP support 11960 Contact Engineering, This is a bug. 11961 Contact Engineering, This is a bug. 11962 Contact Engineering, This is a bug. 11964 Cell online add/delete was attempted but the colad subsystem failed to initialize. Contact HP support. When this event is emitted, cell online add/delete is not usable. 11966 FPARs component on which cell on line add/delete depends is broken or missing.
12048 An invalid or unsupported TPM has been detected in the system. TPM is disabled. Contact HP support 12049 Communication failure between the I/O board and the TPM replace the I/O board. Contact HP support 12050 A CPU module's temperature has exceed the high temperature threshold or a CPU power module Contact HP support personnel to troubleshoot fault has occurred. the problem.
35 Multiple DIMMs have the same serial number. Replace DIMMs with duplicate serial numbers. Ensure new DIMMs have unique serial numbers. 12143 12144 12149 Probable bug in System Firmware, EFI driver, EFI app or OS loader (prior to OS launch). The event data field contains the IVT offset applicable to the interrupt. See table 5-7 (Interruption Vector Provide console log containing register dump to Table) in the Intel ASDM Volume 2. HP Customer Engineer.
12165 A forced power on occurred. Usually this is performed when a normal power on request is denied. The Onboard Administrator may now be running in a non-redundant or over-budget power configuration. Make sure Onboard Administator has the appropriate number and configuration of power supplies. Reduce power required by the blade (for instance, remove some memory or a CPU.) Or, if there are powered-on blades that are not in use, power them off.
12227 OS based diagnostics discovered a hardware problem. 12228 The processor temperature or power has exceeded normal limits. The Enhanced Thermal Management (ETM) feature of the processor has been employed to reduce the chip power to allow operation within normal limits. If this condition persists, this will have an adverse impact on the Check that there are no issues with the cooling, performance of this processor. and if the problem persists contact HP service.
12343 The processor has experienced an excessive number of persistent correctable errors in its third level cache and as a result performance has degraded. Normally the processor can dynamically deal with this type of error with no impact on performance. However, if too many such errors occur then they begin to impact performance. The processor is still able to operate correctly but its performance is degraded so it should be replaced. Contact HP Service for assistance.
Foundation Agent Events Event ID Event Severity Event Description 256 Warning The Foundation Agents service detected an error. The insertion string is: %1. The data contains the error code. 257 Warning The Foundation Agents service could not allocate memory. The data contains the error code. 258 Warning The Foundation Agents service could not register with the Service Control Manager. The data contains the error code.
773 Error The Host Remote Alerter received an error on WaitForMultipleObjects call. The data contains the error code. 774 Error The Host Remote Alerter received an error on ResetEvent call. The data contains the error code. 1105 Informational Foundation Agent: %1 [SNMP TRAP: 11003 in CPQHOST.MIB] 1106 Informational Foundation Agent: %1 [SNMP TRAP: 11004 in CPQHOST.MIB] 1162 Warning Threshold Agent: Rising Threshold Passed. SNMP MIB Variable %1 has value %2 >= %4.
1182 Warning Foundation Agent: Crash dump is not enabled. [SNMP TRAP: 11015 in CPQHOST.MIB] 1183 Warning Foundation Agent: The paging file size of the boot volume (%1) or the target volume of the memory dump file is not large enough to hold a crash dump in the event of a system crash (%2). [SNMP TRAP: 11016 in CPQHOST.MIB] 1792 Warning Component: Foundation SNMP Agent Error: The agent is unable to generate traps due to an error during initialization.
2098 Warning Component: Host Agent Error: Unable to acquire file system information. Cause: This error can be caused by an unformatted partition or by a partition that has been recently modified. Formatting the partition or rebooting the server may correct this err 2099 Warning Component: Host Agent Error: Unable to acquire file system information for %1 Cause: This error can be caused by a low memory condition. Rebooting the server may correct this error.
3087 Warning Debug: The Software Version Agent has failed a set operation on %1. The data contains the value of the attempted set. 3088 Warning Debug: The Software Version Agent has received a set operation for service that is not loaded. The set operation failed. The data contains the current DLL state. 3089 Warning Debug: The Software Version Agent has received a set operation for an unsupported attribute. The set operation failed. The data contains the index of the attempted set.
3875 Warning Component: Cluster Agent Error: Could not open enumerated network. Cause: The Cluster service may not be running. Try to restart the Cluster service. 3876 Warning Component: Cluster Agent Error: Could not enumerate the cluster's networks. Cause: The Cluster service may not be running. Try to restart the Cluster service. 4352 Warning The External Status MIB Agent could not allocate memory. The data contains the error code.
HP System Management Homepage Events Event ID Event Severity 9 Informational The HP System Management Homepage Win32 service has been started successfully. 10 Informational The HP System Management Homepage Win32 service has been stopped successfully. 11 Error The HP System Management Homepage Win32 service could not be started successfully.
5 Error [Management Service] HPIMUTIL: Failed to obtain the Mutex (%s). 5 Error [Management Service] HPIMUTIL: Failed to CreateMutex,Error = %d. 5 Error [Event Synchronization Process] HP Event Synchronization Service failed to initialize IPMI API. 5 Error [Event Synchronization Process] HP Event Synchronization Service has stopped. 5 Error [Event Synchronization Process] HpEvtSyncEx: hMutex CreateMutexError = %d.
5 Error [SNMP Event Agent] Softlog file, %s is corrupted. Fix the Softlog before continuing. Entry: %s. 5 Error [SNMP Event Agent]Error reading from softlog file %s. Breaking the FOR loop. 5 Error [SNMP Event Agent]Error setting file pointer at %s. 5 Error [SNMP Event Agent]Error reading from softlog file %s. 5 Error [SNMP Event Agent] Failed to process SEL Event: %s. 5 Error [SNMP Event Agent] Failed to get the evtLogIgnFlt.cfg path.
5 Error [PFM Process] HPIMUTIL: Failed to CreateMutex,Error = %d. 5 Error [ASR Process] ASR service could not set correctly the time-out in Watchdog timer, error code 0x%X. 5 Error [ASR Process] ASR Watchdog timer could not be correctly reset, error code 0x%X. 5 Error [ASR Process] ASR Watchdog timer could not be correctly disabled, error code 0x%X. 5 Error [ASR Process] ASR Service failed to get IPMI Control due to an exception, error code = 0x%X.
5 Error [Server Agents] IPMI failure: could not obtain IPMI base controller. 5 Error [Server Agents] IPMI failure: could not retrieve watchdog timer registers. 5 Error [Server Agents] IPMI failure: could not obtain FRU inventory data. 5 Error [Server Agents] IPMI failure: could not obtain FRU inventory data while trying to retrieve system product ID. 5 Error [Server Agents] IPMI failure: could not get cell response. 5 Error [Server Agents] IPMI failure: could not get property wrapper.
6 Warning [Event Synchronization Process] Event Synchronization reports: an IPMI error ocurred trying to get the system type. 6 Warning [Event Synchronization Process] Event Synchronization reports: an IPMI error ocurred. 6 Warning [SNMP Event Agent] HP Event Agent has closed its MIB and no System Event Log information will be available through SNMP interface until HP Event Synchronization service is started successfully.
1 Error OutputDirectory string is too long (length > 256). 1 Error Insufficient disk space -- not saving log file. No further logs will be saved until %dMB is available. 1 Error Unable to write error log file %s. 1 Error Unable to open error log file %s. 1 Error Failure checking available disk space. 1 Error Error in record parsing/naming. 1 Error Error writing to file. 1 Error Error writing MCA summary file. 1 Error Error in corrected record parsing/naming.
HP PFM has detected a module replacement: The DIMM %s has been replaced. The serial number of the older module was %s and the serial number of the newer is %s. 2 Informational 2 Informational HP PFM service detected the CPU module in %s has been added. 2 Informational HP PFM service detected the CPU module in %s has been removed. 2 Informational HP PFM service detected the CPU module in %s has been replaced. 2 Informational HP PFM has detected a module replacement: The CPU %s has been replaced.
Component: NIC Agent Error: The NIC Agent cannot communicate with the Token Ring Protocol driver (CNMPROT.SYS). The agent is still functional, but Token Ring MIB II transmissions statistics will not be accurate. Cause: This error can be caused by improperly installed Agents. Re-install the agents. 276 Warning 277 Informational The NIC Agent version %1 has started. 280 Warning The NIC Agent service could not start any agents successfully.
Server Agent Events 140 Event ID Event Severity Event Description 256 Warning The Server Agents service detected an error. The insertion string is: %1. The data contains the error code. 257 Warning The Server Agents service could not allocate memory. The data contains the error code. 258 Warning The Server Agents service could not register with the Service Control Manager. The data contains the error code.
1540 Error Component: System Information Agent%nError: Unable to read from the registry.%n Cause: This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. 1541 Error Debug: The System Information Agent experienced an error while trying to create events for Health monitor thread.Error information follows. 1542 Error Debug: The System Information Agent was unable to start a monitor thread.Error information follows.
1806 Warning Component: Server SNMP Agent%nError: The Server Agent service is not running.%n Cause: The Server SNMP Agent has determined that the Server Agent service is not running. Stop the SNMP service and restart the Server Agents service. If the error persists, reinstalling the Management Agents may correct this error. 1807 Informational Debug: The Server SNMP Agent has determined that the Server Agents service is running.
273 399 400 512 Warning The Storage Agents service could not write the registry value "%1". The data contains the error code. Error The Storage Agents service encountered a fatal error. The service is terminating. The data contains the error code. Informational The Storage Agents service version %1 has started. Warning Error: Unable to allocate memory. Cause: This indicates a low memory condition. Rebooting the system will correct this error. Warning Error: Could not read from the registry subkey.
Error Drive Array Physical Drive Status Change. The physical drive in slot %4, port %5, bay %6 with serial number "%7", has a new status of %2.%n(Drive status values: 1=other, 2=ok, 3=failed, 4=predictiveFailure)%n[SNMP TRAP: 3029 in CPQIDA.MIB] Error Drive Array Accelerator Status Change. The array accelerator board attached to the array controller in slot %4 has a new status of %2.
Error SCSI Tape Drive Status Change.%nThe tape drive with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has a new status of %2.%n(Tape drive status values: 1=other, 2=ok, 3=failed, 5=offline, 6=missingWasOk, 7=missingWasFailed, 8=missingWasOffline)%n [SNMP TRAP: 5016 in CPQSCSI.MIB] Warning SCSI Tape Drive Head Needs Cleaning.%nThe tape drive with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 needs to have a cleaning tape inserted and run.
Warning SCSI Tape Library Failed.%nThe SCSI tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has encountered an error.%n [SNMP TRAP: 5010 in CPQSCSI.MIB] Warning SCSI Tape Library OK.%nThe SCSI tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has recovered from errors.%n [SNMP TRAP: 5011 in CPQSCSI.MIB] Warning SCSI Tape Library Degraded.
1182 Warning Drive Array Tape Drive Status Change. The tape drive in slot %4, SCSI bus %5, SCSI target %6 has a new status of %7.%n(Tape drive status values: 1=other, 2=ok, 3=degraded, 4=failed, 5=offline, 6=missingWasOk, 7=missingWasOffline)%n [SNMP TRAP: 3032 in CPQIDA.MIB] 1183 Warning Drive Array Tape Drive Cleaning Required. The tape drive in slot %4, SCSI bus %5, SCSI target %6 requires cleaning.%n [SNMP TRAP: 3023 in CPQIDA.MIB] Warning Drive Array Tape Drive Replace Cleaning Tape.
Warning External Tape Library Status Change. The tape library at location "%4", has a new status of %7.%n(Library status values: 1=other, 2=ok, 3=degraded, 4=failed, 5=offline)%n [SNMP TRAP: 16026 in CPQFCA.MIB] Warning External Tape Library Door Status Change. The tape library at location "%4", has a new door status of %7.%n(Library door status values: 1=other, 2=notSupported, 3=closed, 4=open)%n [SNMP TRAP: 16027 in CPQFCA.MIB] Warning Drive Array Controller Status Change.
Warning Storage System Temperature Status Change.%nThe %6 %7 storage system connected to SCSI bus %5 of the controller in %4 has a new temperature status of %2.%n(Temperature status values: 1=other,2=ok,3=degraded,4=failed,5=notInstalled) %n [SNMP TRAP: 8027 in CPQSTSYS.MIB] Warning Storage System Fault Tolerant Power Supply Status Change.%nThe fault tolerant power supply in the %6 %7 storage system connected to SCSI bus %5 of the controller in %4 has a new status of %2.
Warning Error: Could not write the registry subkey: "%1". Cause: This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. 1294 Warning Error: Unsupported storage system. Cause: The Proliant storage system %1 is unsupported by this version of the Storage Agents. Upgrade the agents to the latest version. 1343 Warning Error: Duplicate SCSI port found in slot %1. Cause: The current system ROM may not support this SCSI controller.
3590 Warning The IDE Agent could not create an event. The data contains the error code. 3591 Warning The IDE Agent could not open an event. The data contains the error code. 3592 Warning The IDE Agent could not set an event. The data contains the error code. 3593 Warning The IDE Agent could not create a mutex. The data contains the error code. 3594 Warning The IDE Agent could not open a mutex. The data contains the error code.