Windows Integrity Management Agents Reference
This is a system firmware error. Reset the
partition; invalidate NVM on the reporting cell
and reset the partition; or check for newer system
firmware.9495
This is either a system firmware error, or the
wrong I/O is connected to the system. Validate
the system recipe both firmware and hardware.9496
Replaces the I/O card specified by the physical
location.9497
Contact HP Support personnel to check the XBC,
Flex Cables, Backplane, CCs, etc2 or more XBC links are not routable.9498
Contact your HP support representative to check
the affected hardware.
You will receive this message if the memory
system is observing a lot of corrected ECC errors
from a DIMM. The specified DIMM may need to
be serviced.9652
No action is required.
The installed management software has detected
an unstable state of the underlying IPMI
(Intelligent Platform Management Interface)
subsystem and has disabled all management
information from being shown by any
manageability applications. The management
information will become available automatically
as soon as the IPMI subsystem has stabilized.9653
Remove the I/O card from each slot indicated by
an IO_PCI_POWER_OVERLOAD_ERR event.
The I/O configuration's power consumption
exceeds the supported limit.9658
In MFG with Memory SBE Seeding control Flag
(26) Enabled. Should never be seen at a customer's
machine.9659
Contact HP Support personnel to analyze the
fabric.Fabric Access Failure.9661
Contact HP Support to confirm the MP and
PDHC are functioning properly.
A hardware problem exists with MP or PDHC
hardware.9663
An unanticipated error occurred. Contact HP
Support personnel to analyze the IPMI FPL log.9666
Create and distribute a new complex profile using
ParMgr on a functional partition in the complex.
Restore the last complex profile using the "CC"
command from the MP, then use ParMgr to create
a new complex profile. Generate a genesis
complex profile using the "CC" command from
the MP, then use ParMgr to create a new complex
profile.
An error occurred which prevented the complex
profiles from being distributed properly.9668
Contact HP Support personnel to check the CC,
Check XBCFabric AccessError.9670
Contact HP Support to confirm the CPU is
functioning properly.Hardware problem with the CPU.9674
This is a hardware error and it is fatal9678
Correct the error condition (see output of "INFO
WARNING" EFI shell command), reboot the
system, and then initiate O/S boot.
The user has initiated manual O/S boot despite
the existence of a error.9681
Replace the DIMM causing the permanent
memory error in the VGA BIOS region. The PDT
reports which DIMM is causing errors in the
physical address range 0xc0000 - 0xdffff.
Most likely there is a permanent memory error
in the VGA BIOS region (physical address
0xc0000 - 0xdffff).9682
102 Management Agents Event Tables