Windows Integrity Management Agents Reference
NVRAM has become corrupt. Restore from a
backup.9685
Contact HP Support to confirm the CPU is
functioning properly.Hardware problem with the CPU.9695
Contact HP Support to confirm the CPU is
functioning properly.Hardware problem with the CPU.9696
Contact HP support to troubleshoot cell board
Problem on cell wherein PDC could not properly
access memory9697
Contact HP support for possible PDC upgrade
a non-existent/non-accessible register was
specified by software.9698
Contact HP support to troubleshoot cell board
and CPU.Could not update CPU settings9700
Create and distribute a new complex profile using
ParMgr on a functional partition in the complex.
Restore the last complex profile using the "CC"
command from the MP, then use ParMgr to create
a new complex profile. Generate a genesis
complex profile using the "CC" command from
the MP, then use ParMgr to create a new complex
profile.
An error occurred which prevented the complex
profiles from being distributed properly.9701
Contact HP Support to confirm the MP and
PDHC are functioning properly.
A hardware problem exists with MP or PDHC
hardware.9706
check to ensure a valid core cell is configured to
be in the partition.most likely a configuration problem,9707
check partition configuration, check for failed
cells.
Configuration error, fabric failure; the intended
core cell failed during boot.9708
Check partition configuration, Check for failed
cells, as indicated by high-alert level IPMI events
earlier in the boot.
Configuration error, Mainbackplane failure, The
intended core cell failed during boot.9709
check partition configuration, check for failed
cells, check for additional chassis codes indicating
more failure detail.
Configuration error, main backplane failure; the
intended core cell failed during boot.9710
check partition configuration, attach core I/O to
local cell, make sure a viable core cell is
configured within the partition.
Configuration error, main backplane failure; no
viable core cell.9711
Contact HP Support to confirm the main
backplane is functioning properly. Change the
partition configuration to only contain 1 or 2 cells.
configuration combined with main backplane
problems.9712
replace the PDH hardware.
there is a known issue with some Dallas
Semiconductor DS1501 RTC parts that can cause
read data anomalies but they should never be
this consistent, this event indicates faulty PDH
hardware.9719
Contact HP support to confirm that the main
backplane is functioning properly.
PDC was unable to read a data structure for
another cell in the partition. This should never
happen unless there is an intermittent problem
with the main backplane.9727
Reset cell.Firmware error.9740
Check flex cable indicated by event data.
The particular XBC and port could have a
persistent error.9741
Platform Events – Table 2 (Windows System Log Event ID, Cause, Recommended Action) 103