Windows Integrity Management Agents Reference
Cells exist in both cabinets, but one of the cabinets
has no cells powered on. If a 2 cabinet
configuration is desired, shutdown any active
partitions and power off both cabinets and then
power them both on, including at least 1 cell in
each cabinet. (Note: it is possible to get this event
ID and have both cabinets powered on. In this
event, no action is required.)9742
No action can be taken. The result is some or all
PCI error logs will be unavailable.
An error occurred while collecting the PCI error
logs9744
No action can be taken. The result is some or all
SBA error logs will be unavailable.
An error occurred while collecting the SBA error
logs9745
Check for hardware failures. Reset backplane to
re-initialize fabric.
Hardware problem. Possible bad XBC or Cell
Controller9746
If you receive this message, contact your support
provider to determine if a predictive repair
should be made.
You will receive this message if the system is
correcting a lot of ECC single bit errors. It may
mean that the module is about to fail, or
environmental conditions in the server are
causing more errors than usual. This event
message will be generated for one of the
following conditions 1000 single-bit errors on the
same address in a 48 hour time period. 50
single-bit errors on the same DIMM (not the same
address) in a 24 hour time period. 100 single-bit
errors on the same DIMM (not the same address)
in a 1 week time period.9750
If you receive this message, contact your support
provider to determine if a predictive repair
should be made.
You will receive this message if the system is
correcting a lot of ECC single bit errors. It may
mean that the module is about to fail, or
environmental conditions in the server are
causing more errors than usual. This event
message will be generated for one of the
following conditions 1500 single-bit errors on the
same address in a 72 hour time period. 120
single-bit errors on the same DIMM (not the same
address) in a 24 hour time period. 130 single-bit
errors on the same DIMM (not the same address)
in a 1 week time period.9751
An unexpected but random error occurred.
Reboot the system. There is a problem with the
system bus. Contact your HP representative to
check the system bus.9753
Reboot the system.An unexpected but random error occurred.9754
An unexpected but random error occurred.
Reboot the system. There is a problem with the
system bus. Contact your HP representative to
check the system bus. Check the system forward
progress log (available from the Management
Processor) for additional information about this
problem.9755
AC power cycle the system . If this doesn't work,
contact HP support.
FW tried to read the first boot token and received
a failure.9768
replace IA cell with PA cell or reconfigure
partition to exclude the IA cell.other cell is an IA cell9769
Contact HP Support personnel to analyze the
fabric.
Fabric Access Failure. Could not write to the XBC.
This could indicate a hardware problem. Include
the FABRIC_ERRORS_XBC_CLEAR_WR_ADDR
event log and its data in any reports.9774