Windows Integrity Management Agents Reference

Verify that the default settings are appropriate.
For example, run the EFI baud and boot test
command.
Both SAL's copy and BMC copy of the token
specified in the data field is bad. SFW is
reinitializing that token to it's default value10628
Remove I/O backplane and/or I/O backplane
cables and replace with compatible I/O backplane
and/or I/O backplane cables.
Incorrect I/O backplane and/or I/O backplane
cables are connected to the cell board. The cell
board is not compatible with I/O backplane
and/or I/O backplane cables.10629
Initialize the NVRAM to the factory defaults and
reset the server. Soft partitions will have to be
recreated from scratch before they are available.
Firmware ran out of NVRAM before the server
completed cold boot initialization.10698
Initialize the NVRAM to the factory defaults and
reset the server. Soft partitions will have to be
recreated from scratch before they are available.
Firmware ran out of NVRAM before the server
completed cold boot initialization.10702
This should not show up and Firmware should
have resolved this.10703
Restore NVRAM to factory defaults. Reset server
and reconfigure soft partitions.NVRAM corruption of fPars specific database.10704
Restore NVRAM to factory defaults. Reset server
and reconfigure soft partitions.NVRAM corruption of fPars specific database.10705
Restore NVRAM to factory defaults. Reset server
and reconfigure soft partitions.NVRAM corruption of fPars specific database.10706
Restore NVRAM to factory defaults. Reset server
and reconfigure soft partitions.NVRAM corruption of fPars specific database.10707
Restore NVRAM to factory defaults. Reset server
and reconfigure soft partitions.NVRAM corruption of fPars specific database.10708
Delete some EFI variables in existing fPars or boot
in nPars mode and delete some variables. (E.g.,
too many boot paths in the boot manager can
cause this). Clear NVRAM and reconfigure
system.NVRAM is too full for operation.10771
Try booting nPars mode. Power cycle the
hardware. replace the LBA
Low level IO hw initialization of an LBA by the
firmware failed during an fPar reset.10772
Contact your HP support representative.
The CPU modules have been installed in an
illegal configuration on the cell board.10779
Contact your HP support representative.
An invalid CPU terminator card is installed on
the cell board.10780
Reset the nPar.An error in the system firmware.10793
Reset the nPar.An error in the system firmware.10794
No action is required. The nPar will be rebooted.
Fpar reset to an Fpar which failed to release
critical resources within a reasonable time.10795
Contact your HP support representative to check
your memory system.
You will receive this message if the system is
observing a lot of corrected ECC errors in
memory. This could be caused by problems with
the system's memory or by unexpected
environmental conditions inside the server.10814
The firmware has already taken necessary action.
Once the temperature comes down, the firmware
will restore the processor's performance to normal
The processor temperature is above the operating
range. The processor's performance is throttled
by the firmware to reduce the temperature10822
112 Management Agents Event Tables