Windows Integrity Management Agents Reference

Contact HP support
An invalid or unsupported TPM has been
detected in the system. TPM is disabled.12048
replace the I/O board. Contact HP support
Communication failure between the I/O board
and the TPM12049
Contact HP support personnel to troubleshoot
the problem.
A CPU module's temperature has exceed the high
temperature threshold or a CPU power module
fault has occurred.12050
Reboot, if problem persists, contact HP supportCosmic radiation Bad flash part12069
power down slot attempting to remove PCI card.
PCI interlock has been opened with PCI slot
power on.12091
Check the backplane.A defective component could cause this fault.12101
Check the main backplane.
The specified low dropout regulator on the main
backplane is reporting a fault.12102
Check the specified core IO.
The hot swap controller for the specified core IO
is reporting fault.12103
Capture IPMI event logs, look for additional
errors. Contact your HP Support Representative
to analyze the fabric
System firmware had difficulty determining the
crossbar number from the graph data structure12109
Reconfigure the partition or reset the CLM setting
on one or more cells in your partition using the
Partition Manager or ParCLI tools.
The initial partition configuration may have not
specified 100% Cell-Local Memory or may have
been reconfigured incorrectly.12119
Contact your HP support representative to check
the specified memory.
System firmware has detected and corrected
memory errors. Double DRAM chip sparing
events have been invoked to help mitigate this
condition. On the next reboot, system firmware
will test the specified memory components, and
may take them offline if the errors persist.12120
Monitor the situation and contact your HP
support representative to check the affected
hardware.
Hardware has detected many link retries on one
of its channels and has switched to a spare one.12121
Contact your support representative to have the
backplane and / or connections between
backplanes checked
The error occurred between the crossbar chips
on the backplane(s).12127
Contact your support representative to have the
Cell Controller to IO Interface checked. Check
these FRUs: Cell-IO cable, IO chassis, IO
backplane, cell, or system backplane
The error occurred between the cell controller
and the IO controller.12128
Contact your support representative to have the
Cell Controller to backplane Interface checked.
The errors occurred between the cell controller
and the backplane.12129
Contact your support representative to have the
backplane and / or connections between
backplanes checked.
The errors occurred between the crossbar chips
on the backplane(s).12130
Contact your support representative to have the
Cell Controller to IO Interface checked. Check
these FRUs: Cell-IO cable, IO chassis, IO
backplane, cell, or system backplane.
The errors occurred between the cell controller
and the IO controller.12131
Contact your support representative to have the
server identification information and cabinet type
checked.
The cabinet type is not in agreement with the
server identification information. The server
identification information is viewable using the
ID command from the MP's command menu. The
cabinet type is displayed in the top line of the
cabinet status shown when the PS command from
the MP's command menu is used to target a
compute cabinet.12132
120 Management Agents Event Tables