Windows Integrity Management Agents Reference

Drive Array Physical Drive Status Change. The physical drive in slot %4, port %5,
bay %6 with serial number "%7", has a new status of %2.%n(Drive status values:
1=other, 2=ok, 3=failed, 4=predictiveFailure)%n[SNMP TRAP: 3029 in CPQIDA.MIB]Error1064
Drive Array Accelerator Status Change. The array accelerator board attached to the
array controller in slot %4 has a new status of %2.%n(Accelerator status values:
1=other, 2=notConfigured, 3=enabled, 4=tmpDisabled, 5=permDisabled)%n [SNMP
TRAP: 3025 in CPQIDA.MIB]Error1065
Drive Array Accelerator Bad Data. The array accelerator board attached to the array
controller in slot %4 is reporting that it contains bad cached data.%n[SNMP TRAP:
3026 in CPQIDA.MIB]Error1066
Drive Array Accelerator Battery Failed. The array accelerator board attached to the
array controller in slot %4 is reporting a battery failure.%n[SNMP TRAP: 3027 in
CPQIDA.MIB]Error1067
SCSI Controller Status Change.%nThe SCSI controller in slot %4, SCSI bus %5 has a
new status of %2.%n(Controller status values: 1=other, 2=ok, 3=failed)%n[SNMP
TRAP: 5005 in CPQSCSI.MIB]Error1068
SCSI Logical Drive Status Change.%nThe SCSI logical drive with SCSI target %6
connected to SCSI bus %5 of the controller in slot %4 has a new status of %2.%n(Drive
status values: 1=other, 2=ok, 3=failed, 4=unconfigured, 5=recovering,
6=readyForRebuild, 7=rebuilding, 8=wrongDrive, 9=badConnect, 10=degraded,
11=disabled)%n [SNMP TRAP: 5021 in CPQSCSI.MIB]Error1069
SCSI Physical Drive Status Change.%nThe SCSI physical drive with SCSI target %6
connected to SCSI bus %5 of the controller in slot %4 has a new status of %2.%n(Drive
status values: 1=other, 2=ok, 3=failed, 4=notConfigured, 5=badCable, 6=missingWasOk,
7=missingWasFailed, 8=predictiveFailure, 9=missingWasPredictiveFailure, 10=offline,
11=missingWasOffline)%n [SNMP TRAP: 5020 in CPQSCSI.MIB]Error1070
Storage System Fan Status Change.%nThe %6 %7 storage system connected to SCSI
bus %5 of the controller in slot %4 has a new status of %2.%n(Fan status values:
1=other, 2=ok, 3=failed, 4=notInstalled, 5=degraded)%n [SNMP TRAP: 8008 in
CPQSTSYS.MIB]Warning1075
Storage System Temperature Failure.%nThe %6 %7 storage system connected to SCSI
bus %5 of the controller in slot %4 has a failed temperature status. Shutdown the
storage system as soon as possible.%n [SNMP TRAP: 8009 in CPQSTSYS.MIB]Error1076
Storage System Temperature Degraded.%nThe %6 %7 storage system connected to
SCSI bus %5 of the controller in slot %4 system has a temperature outside the normal
operating range.%n [SNMP TRAP: 8010 in CPQSTSYS.MIB]Warning1077
Storage System Temperature OK.%nThe temperature in the %6 %7 storage system
connected to SCSI bus %5 of the controller in slot %4 has returned to the normal
operating range.%n [SNMP TRAP: 8011 in CPQSTSYS.MIB]Informational1078
Drive Array Physical Drive Monitoring is not enabled. The physical drive in slot %4,
port %5, bay %6 with serial number "%7", does not have drive threshold monitoring
enabled.Informational1098
Storage System Side Panel Removed.%nThe side panel has been removed on the %6
%7 storage system connected to SCSI bus %5 of the controller in slot %4.%n [SNMP
TRAP: 8013 in CPQSTSYS.MIB]Warning1101
Storage System Side Panel In Place.%nThe side panel has been replaced on the %6
%7 storage system connected to SCSI bus %5 of the controller in slot %4.%n [SNMP
TRAP: 8012 in CPQSTSYS.MIB]Informational1102
Storage System Fault Tolerant Power Supply Degraded.%nThe fault tolerant power
supply in the %6 %7 storage system connected to SCSI bus %5 of the controller in
slot %4 has a degraded status. Restore power or replace any failed power supply.%n
[SNMP TRAP: 8015 in CPQSTSYS.MIB]Warning1104
144 Management Agents Event Tables