Windows Integrity Management Agents Reference
SCSI Tape Drive Status Change.%nThe tape drive with SCSI target %6 connected to
SCSI bus %5 of the controller in slot %4 has a new status of %2.%n(Tape drive status
values: 1=other, 2=ok, 3=failed, 5=offline, 6=missingWasOk, 7=missingWasFailed,
8=missingWasOffline)%n [SNMP TRAP: 5016 in CPQSCSI.MIB]Error1107
SCSI Tape Drive Head Needs Cleaning.%nThe tape drive with SCSI target %6
connected to SCSI bus %5 of the controller in slot %4 needs to have a cleaning tape
inserted and run.%n [SNMP TRAP: 5008 in CPQSCSI.MIB]Warning1119
SCSI Tape Drive Cleaning Tape Needs Replacing.%nThe tape drive with SCSI target
%6 connected to SCSI bus %5 of the controller in slot %4 needs the cleaning tape
replaced.%n [SNMP TRAP: 5009 in CPQSCSI.MIB]Warning1120
IDE Drive Status Degraded.%nThe IDE drive %4 has a degraded status and should
be scheduled for replacement.%n [SNMP TRAP: 14001 in CPQIDE.MIB]Warning1121
IDE Drive Status OK.%nThe IDE drive %4 has returned to a normal operating
condition.%n [SNMP TRAP: 14002 in CPQIDE.MIB]Informational1122
External Array Logical Drive Status Change. Logical drive number %5 on array "%4"
has a new status of %6.%n(Logical Drive status values: 1=other, 2=ok, 3=failed,
4=unconfigured, 5=recovering, 6=readyForRebuild, 7=rebuilding, 8=wrongDrive,
9=badConnect, 10=overheating, 11=shutdown, 12=expanding, 13=notAvailable,
14=queuedForExpansion)%n [SNMP TRAP: 16022 in CPQFCA.MIB]Error1145
External Array Physical Drive Status Change. The physical drive in port %5, bay %6
on array "%4" has a new status of %7.%n(Drive status values: 1=other, 2=unconfigured,
3=ok, 4=threshExceeded, 5=predictiveFailure, 6=failed)%n [SNMP TRAP: 16016 in
CPQFCA.MIB]Error1146
External Array Spare Drive Status Change. The spare drive in port %5, bay %6 on
array "%4" has a new status of %7.%n(Spare status values: 1=other, 2=inactive, 3=failed,
4=building, 5=active)%n [SNMP TRAP: 16002 in CPQFCA.MIB]Error1147
External Array Accelerator Status Change. The array accelerator board attached to
the external controller in I/O slot %5 of array "%4" has a new status of
%6.%n(Accelerator status values: 1=other, 2=notConfigured, 3=enabled,
4=tmpDisabled, 5=permDisabled)%n [SNMP TRAP: 16017 in CPQFCA.MIB]Error1148
External Array Accelerator Bad Data. The array accelerator board attached to the
external controller in I/O slot %5 of array "%4" is reporting that it contains bad cached
data.%n [SNMP TRAP: 16018 in CPQFCA.MIB]Error1149
External Array Accelerator Battery Failed. The array accelerator board attached to
the external controller in I/O slot %5 of array "%4" is reporting a battery failure.%n
[SNMP TRAP: 16019 in CPQFCA.MIB]Error1150
External Array Controller Status Change. The external controller in I/O slot %5 of
array "%4" has a new status of %6.%n(Controller status values: 1=other, 2=ok, 3=failed,
4=offline, 5=redundantPathOffline)%n [SNMP TRAP: 16020 in CPQFCA.MIB]Error1151
Storage System Fan Module Status Change. Storage system "%4" fan module at
location %5 has a new status of %6.%n(Fan module status values: 1=other,
2=notInstalled, 3=ok, 4=degraded, 5=failed)%n [SNMP TRAP: 8020 in CPQSTSYS.MIB]Warning1152
Storage System Power Supply Status Change. Storage system "%4" power supply at
location %5 has a new status of %6.%n(Power supply status values: 1=other,
2=notInstalled, 3=ok, 4=failed, 5=degraded)%n [SNMP TRAP: 8021 in CPQSTSYS.MIB]Warning1153
Storage System Power Supply UPS Status Change. The UPS attached to storage
system "%4" power supply bay %5 has a new status of %7.%n(Power supply UPS
status values: 1=other, 2=noUps, 3=ok, 4=powerFailed, 5=batteryLow)%n [SNMP
TRAP: 8018 in CPQSTSYS.MIB]Warning1154
Storage System Temperature Sensor Status Change. Storage system "%4" temperature
sensor at location %5 has a new status of %6 and a current temperature value of %7
celsius.%n(Temperature sensor status values: 1=other, 2=ok,3=degraded, 4=failed)%n
[SNMP TRAP: 8019 in CPQSTSYS.MIB]Warning1155
Storage Agent Events 145