Windows Integrity Management Agents Reference
Storage System Temperature Status Change.%nThe %6 %7 storage system connected
to SCSI bus %5 of the controller in %4 has a new temperature status of
%2.%n(Temperature status values: 1=other,2=ok,3=degraded,4=failed,5=notInstalled)
%n [SNMP TRAP: 8027 in CPQSTSYS.MIB]Warning1213
Storage System Fault Tolerant Power Supply Status Change.%nThe fault tolerant
power supply in the %6 %7 storage system connected to SCSI bus %5 of the controller
in %4 has a new status of %2.%n(Power supply status values:
1=other,2=ok,3=degraded, 4=failed,5=notInstalled)%n [SNMP TRAP: 8028 in
CPQSTSYS.MIB]Warning1214
Fibre Channel Controller Status Change. The Fibre Channel Controller in %4 has a
new status of %5.%n(Host controller status values: 1=other, 2=ok, 3=failed,
4=shutdown, 5=connectionDegraded, 6=connectionFailed)%n [SNMP TRAP: 16028
in CPQFCA.MIB]Warning1215
Drive Array Physical Drive Status Change. The physical drive in %4, %5 with serial
number "%7", has a new status of %2. %n(Drive status values: 1=other, 2=ok, 3=failed,
4=predictiveFailure) %n [SNMP TRAP: 3046 in CPQIDA.MIB]Warning1216
Drive Array Spare Drive Status Change. The spare drive in %4, %5 has a new status
of %2.%n(Spare status values: 1=other, 2=invalid, 3=failed, 4=inactive,
5=building,6=active) %n [SNMP TRAP: 3047 in CPQIDA.MIB]Warning1217
Storage System Fan Status Change.%nThe %6 %7 storage system connected to %5
of the controller in %4 has a new status of %2.%n(Fan status values: 1=other, 2=ok,
3=failed, 4=notInstalled, 5=degraded)%n [SNMP TRAP: 8029 in CPQSTSYS.MIB]Warning1218
Storage System Temperature Status Change.%nThe %6 %7 storage system connected
to %5 of the controller in %4 has a new temperature status of %2.%n(Temperature
status values: 1=other,2=ok,3=degraded,4=failed,5=notInstalled) %n [SNMP TRAP:
8030 in CPQSTSYS.MIB]Warning1219
Storage System Fault Tolerant Power Supply Status Change.%nThe fault tolerant
power supply in the %6 %7 storage system connected to %5 of the controller in %4
has a new status of %2.%n(Power supply status values: 1=other,2=ok,3=degraded,
4=failed,5=notInstalled)%n [SNMP TRAP: 8031 in CPQSTSYS.MIB]Warning1220
SAS/SATA Physical Drive Status Change. The physical drive in %4, %5 with serial
number "%6", has a new status of %7. %n(Drive status values: 1=other, 2=ok,
3=predictiveFailure, 4=offline, 5=failed, 6=missingWasOk,
7=missingWasPredictiveFailure, 8=missingWasoffline, 9=missingWasFailed) %n
[SNMP TRAP: 5022 in CPQSCSI.MIB]Warning1221
SAS/SATA Logical Drive Status Change. Logical drive number %5 on the HBA in
%4 has a new status of %6.%n(Logical Drive status values: 1=other, 2=ok, 3=degraded,
4=rebuilding, 5=failed) %n [SNMP TRAP: 5023 in CPQSCSI.MIB]Warning1222
SAS Tape Drive Status Change. The tape drive in %4, %5 with serial number "%6",
has a new status of %7. %n(Tape Drive status values: 1=other, 2=ok, 3=offline) %n
[SNMP TRAP: 5025 in CPQSCSI.MIB]Warning1223
Error: Unable to allocate memory. Cause: This indicates a low memory condition.
Rebooting the system will correct this error.Warning1280
Error: Could not read from the registry subkey. Cause: This error can be caused by
a corrupt registry or a low memory condition. Rebooting the server may correct this
error.Warning1281
Error: Could not write the registry subkey: "%1". Cause: This error can be caused by
a corrupt registry or a low memory condition. Rebooting the server may correct this
error.Warning1282
Error: Could not read the registry subkey: "%1". Cause: This error can be caused by
a corrupt registry or a low memory condition. Rebooting the server may correct this
error.Warning1283
Error: Could not write the registry subkey: "%1". Cause: This error can be caused by
a corrupt registry or a low memory condition. Rebooting the server may correct this
error.Warning1284
Storage Agent Events 149