Windows Integrity Management Agents Reference

hpevtEfiPosseLibNotInit - 5784 in
HPIFPTRAP.MIBEFI unable to initialize internal libraryError5784
hpevtEfiSecurityNotInit - 5785 in
HPIFPTRAP.MIBEFI unable to initialize security systemError5785
hpevtEfiSecInvalidSysmode - 5786 in
HPIFPTRAP.MIBEFI detected invalid internal privilege levelWarning5786
hpevtEfiSecSetPassLevelErr - 5787 in
HPIFPTRAP.MIB
EFI detected invalid privilege level when
setting passwordWarning5787
hpevtMdtBad - 5788 in HPIFPTRAP.MIBEFI MDT table is badError5788
hpevtBootCpuBadCoreFixedRatio - 5790
in HPIFPTRAP.MIBProcessor has incompatible fixed core ratioWarning5790
hpevtBootAllCpusSlatedForCompatDeconfig
- 5791 in HPIFPTRAP.MIB
All processors slated for compatibility
deconfigurationError5791
hpevtXbcReadRemoteRouteError - 5793
in HPIFPTRAP.MIB
An unexpected or invalid value was read
from a crossbar remote route table.Error5793
hpevtXbcReadNeighborInfoError - 5794
in HPIFPTRAP.MIB
Error reading the
PORT[n]_NEIGHBOR_INFO XBC CSR.Error5794
hpevtMemDimmQuadMismatch - 5795
in HPIFPTRAP.MIBmemory DIMM quad mis-matchWarning5795
hpevtMemDimmFailed - 5796 in
HPIFPTRAP.MIB
Firmware detected excessive errors on the
DIMM.Warning5796
hpevtXbcPortOeError - 5797 in
HPIFPTRAP.MIB
The OE (output enable) bit was not set for a
XBC port.Error5797
hpevtXbcPortStatusError - 5798 in
HPIFPTRAP.MIB
An error occurred while trying to read the
PORT_STATUS CSR for a XBC port.Error5798
hpevtXbcPortLandmined - 5799 in
HPIFPTRAP.MIB
A XBC port was unexpectedly found to be
landmined.Error5799
hpevtPdIncompatibleCpuSpeeds - 5800
in HPIFPTRAP.MIB
CPUs running at different speeds were
detected during rendezvousError5800
hpevtFabricCellLinkNotInit - 5802 in
HPIFPTRAP.MIB
The link between the local CC and the local
XBC is unexpectedly not initialized.Error5802
hpevtFabricInvalidXbcNum - 5803 in
HPIFPTRAP.MIBAn invalid XBC number was given.Error5803
hpevtFabricInvalidXbcPortNum - 5804
in HPIFPTRAP.MIBAn invalid XBC port number was given.Error5804
hpevtUtilitiesLedParamError - 5805 in
HPIFPTRAP.MIB
A bad parameter was passed to the LED
function in the utilities componentWarning5805
hpevtFabricUnexpectedNtype - 5806 in
HPIFPTRAP.MIB
An unexpected neighbor type was read from
a XBC PORT_NEIGHBOR_INFO CSR.Error5806
hpevtFabricPortNotCc - 5807 in
HPIFPTRAP.MIBA given XBC port is not a valid XBC-CC port.Error5807
hpevtFabricPortNotXbc - 5808 in
HPIFPTRAP.MIB
A XBC port was unexpectedly found to be
an invalid XBC-XBC port.Error5808
hpevtFabricUnexpectedNChip - 5809 in
HPIFPTRAP.MIB
The XBC neighbor chip number does not
match the expected value for this topologyError5809
hpevtFabricUnexpectedNPort - 5810 in
HPIFPTRAP.MIB
The XBC neighbor port number does not
match the expected value for this topologyError5810