Windows Integrity Management Agents Reference
hpevtPdhcWatchdogTimedOut - 7774 in
HPIFPTRAP.MIB
PDHC FW was reset by hardware due to
firmware inactivity.Warning7774
hpevtAbortPowerupOth - 7781 in
HPIFPTRAP.MIBPower Up Aborted, Over TempWarning7781
hpevtAbortPwrupBps - 7782 in
HPIFPTRAP.MIBToo Few Bulk Power Supplies AvailableError7782
hpevtAbortStartBlowr - 7783 in
HPIFPTRAP.MIBNo Cabinet Start, Insufficient BlowersError7783
hpevtAbortStartIofan - 7784 in
HPIFPTRAP.MIBNo Cabinet Start, Insufficient IO FansError7784
hpevtAcDeleted - 7786 in
HPIFPTRAP.MIB
AC power to the PDCA was removed. Data
Byte 3 specifies PDCA number.Warning7786
hpevtBlowrFail - 7791 in
HPIFPTRAP.MIBCabinet Main Blower FailedWarning7791
hpevtBpsFail48flt - 7793 in
HPIFPTRAP.MIB
48 Volt Converter Failed. Data Byte 3
specifies PDCA number.Warning7793
hpevtBpsFailFanflt - 7795 in
HPIFPTRAP.MIBFan failed in designated Bulk Power SupplyWarning7795
hpevtBpsFailOt - 7796 in
HPIFPTRAP.MIB1 Side Converter Over TempWarning7796
hpevtBpsNotRedundant - 7798 in
HPIFPTRAP.MIBBulk Power Supplies are not Redundant.Warning7798
hpevtBpsOvervoltage - 7799 in
HPIFPTRAP.MIB+48V DC has exceeded its upper limitError7799
hpevtBpsUndervoltage - 7803 in
HPIFPTRAP.MIB+48V DC has fallen below its lower limitError7803
hpevtCabFanFail - 7806 in
HPIFPTRAP.MIBCabinet Fan FailedWarning7806
hpevtHkpOvervoltage - 7822 in
HPIFPTRAP.MIB
Housekeeping power has exceeded expected
levels.Error7822
hpevtHkpUndervoltage - 7823 in
HPIFPTRAP.MIB
Housekeeping power has fallen below
expected levels.Error7823
hpevtIllegalBpsCfgOrPhaseFlt - 7824 in
HPIFPTRAP.MIB
The BPSs for the cabinet are illegally
configured. Data Byte 3 = PDCA number.Warning7824
hpevtIllegalBpsid - 7825 in
HPIFPTRAP.MIB
BPS ID received from installed Bulk Power
Supply was unknownWarning7825
hpevtInletOvertempHi - 7827 in
HPIFPTRAP.MIBAmbient Air Sensor OvertempWarningError7827
hpevtInletOvertempLo - 7828 in
HPIFPTRAP.MIBAmbient Air Sensor OvertempWarningWarning7828
hpevtInletOvertempMid - 7829 in
HPIFPTRAP.MIBAmbient Air Sensor OvertempWarningError7829
hpevtIofanFail - 7836 in HPIFPTRAP.MIBIO Fan FailedWarning7836
hpevtPowerOverload - 7842 in
HPIFPTRAP.MIBCabinet Power System is in overload.Warning7842
hpevtShutdownBlowr - 7845 in
HPIFPTRAP.MIBCabinet Shutdown - Insufficient BlowersError7845
Platform Events – Table 1 (Windows System Log Event ID, Severity, Description, SNMP Trap) 27