Windows Integrity Management Agents Reference
hpevtOptsBlockCksumError - 8883 in
HPIFPTRAP.MIBOption block in nvram has a checksum errorWarning8883
hpevtFabricColaLocalCcLinkNotInit -
8894 in HPIFPTRAP.MIB
CC to CC link did not initialize on the local
cellWarning8894
hpevtFabricXinInitDisableWrError - 8895
in HPIFPTRAP.MIBFailed to write the CC link disable registerWarning8895
hpevtFabricXinErrMaskUnknownBkp -
8896 in HPIFPTRAP.MIBAn unknown backplane type was foundWarning8896
hpevtFabricXinWrErrMaskError - 8897
in HPIFPTRAP.MIBError writing the CC link error maskWarning8897
hpevtFabricXinRdErrMaskError - 8898
in HPIFPTRAP.MIBFailed to read the CC's fabric link error maskWarning8898
hpevtFabricInitCcLinkFailure - 8900 in
HPIFPTRAP.MIB
Could not initialize the CC to CC link upon
boot.Error8900
hpevtResetCommandError - 8906 in
HPIFPTRAP.MIB
AnError occurred trying to notify the MP of
the attempted reset.Warning8906
hpevtErrAssertData - 8924 in
HPIFPTRAP.MIB
Error Data tied to a previousError Assert
eventWarning8924
hpevtFabricInitCcLinkDisableErr - 8926
in HPIFPTRAP.MIB
Failed disabling the XIN link for a single cell
modelWarning8926
hpevtFabricSetPortStateGetSm4Err - 8930
in HPIFPTRAP.MIBError while getting the XBC SemaphoreError8930
hpevtFabricSetPortStateRlsSm4Err - 8931
in HPIFPTRAP.MIBError releasing the XBC SemaphoreWarning8931
hpevtFabricAssertFabricErr - 8936 in
HPIFPTRAP.MIBUnexpected fabric firmware errorWarning8936
hpevtFabricXinLinkAlreadyInit - 8939 in
HPIFPTRAP.MIB
The CC's XIN link was found to be already
initializedWarning8939
hpevtNoCpuModulesFoundByPdhc -
8940 in HPIFPTRAP.MIB
Cell has been disabled by the PDHC because
no CPU modules were found.Error8940
hpevtCpuModCompatMismatch - 8941
in HPIFPTRAP.MIB
Cell has been disabled by PDHC FW because
the CPU modules are not compatible.Error8941
hpevtBadCpuModScratchCksum - 8942
in HPIFPTRAP.MIB
Cell has been disabled because of invalid data
in a CPU module Scratch EEPROM.Error8942
hpevtPdhBatteryLowWarning - 8954 in
HPIFPTRAP.MIBThe Cell Battery voltage level low warningWarning8954
hpevtFabricRouteXbcCopyRoutingErr -
8959 in HPIFPTRAP.MIB
Error while copying the XBC routing to the
local portError8959
hpevtFabricCopyRdBackFailed - 8960 in
HPIFPTRAP.MIBA read after write of a XBC CSR failedError8960
hpevtFabricRtgCompleteSm4RlsErr -
8962 in HPIFPTRAP.MIB
Couldn't release the Semaphore while writing
routing states.Warning8962
hpevtFabricRtgCompleteWrFwdPrgErr
- 8964 in HPIFPTRAP.MIB
Couldn't write the XBC's forward progress
registerError8964
hpevtFabricRtgCompleteSm4AccessErr
- 8965 in HPIFPTRAP.MIBCouldn't access the XBC semaphore registers.Error8965
hpevtFabricRtgCompleteTopologyErr -
8966 in HPIFPTRAP.MIB
Couldn't determine the complex fabric
topologyError8966
Platform Events – Table 1 (Windows System Log Event ID, Severity, Description, SNMP Trap) 35