Windows Integrity Management Agents Reference

hpevtCpuTempExceedHiThres - 12050
in HPIFPTRAP.MIB
A CPU module's temperature has exceed the
high temperature threshold or a CPU power
module fault has occurred. As a result of this
event, the CPU has been inhibited. The Cell
must be powered off then on using the MP's
PE command to clear.Error12050
hpevtSFWDetErrStablStorFlsh - 12069 in
HPIFPTRAP.MIB
SFW detected an error while writing to stable
store flash.Warning12069
hpevtInlckOpenPCIPwr - 12091 in
HPIFPTRAP.MIBPCI interlock open with PCI power applied.Warning12091
hpevtFaltDetDropRegIO - 12101 in
HPIFPTRAP.MIB
Fault detected on low drop out regulator on
I/O backplane.Error12101
hpevtFaltDetDropRegManBckPlne -
12102 in HPIFPTRAP.MIB
Fault detected on low drop out regulator on
main backplane.Error12102
hpevtFaltDetHotswpCoreIO - 12103 in
HPIFPTRAP.MIB
Fault detected hot swap controller of
specified core IO.Error12103
hpevtErrRetrvCrssbarChipNmbr - 12109
in HPIFPTRAP.MIB
An error occurred while retrieving the
crossbar chip number.Warning12109
hpevtCellNotCfgCLMMode - 12119 in
HPIFPTRAP.MIB
One or more of the cells are not configured
for Cell-Local Memory (CLM) modeWarning12119
hpevttDoblDramInvoke - 12120 in
HPIFPTRAP.MIB
Double DRAM chip sparing events have been
invoked.Warning12120
hpevtErrCrssbarCrctByHW - 12121 in
HPIFPTRAP.MIB
A platform error was detected by the
firmware/hardware, and corrected by using
a spare channel.Warning12121
hpevtErrCrssChipBckPln - 12127 in
HPIFPTRAP.MIB
A platform error was detected by the
firmware/hardware, and corrected by using
a spare channel.Warning12127
hpevtErrCeLLIO - 12128 in
HPIFPTRAP.MIB
A platform error was detected by the
firmware/hardware, and corrected by using
a spare channel.Warning12128
hpevtMltPltFrmErrCellBckPln - 12129 in
HPIFPTRAP.MIB
Multiple platform errors were detected and
corrected by the firmware/hardware.Warning12129
hpevtMultPltFrmErrCrssChpBckPln -
12130 in HPIFPTRAP.MIB
Multiple platform errors were detected and
corrected by the firmware/hardware.Warning12130
hpevtMultPltFrmErrCeLLIO - 12131 in
HPIFPTRAP.MIB
Multiple platform errors were detected and
corrected by the firmware/hardware.Warning12131
hpevtServIDNotMatchCab - 12132 in
HPIFPTRAP.MIB
The server ID does not match the cabinet
type.Error12132
hpevtDupDimNumDetect - 12135 in
HPIFPTRAP.MIB
Duplicate DIMM serial numbers have been
detected. Data field gives physical location
of DIMM. Check for other events specifying
other DIMMs with same serial number.Warning12135
hpevtMPLostUPS - 12143 in
HPIFPTRAP.MIB
The MP has lost lan communication with the
UPS.Warning12143
hpevtMPGainLanCommUPS - 12144 in
HPIFPTRAP.MIB
The MP has re-gained lan communication
with the UPS.Warning12144
hpevtUnrecovProcIFAinterptInFW -
12149 in HPIFPTRAP.MIB
An unrecoverable processor interrupt
occurred while in IPF firmware. The data
value is the processor IFA.Error12149
58 Management Agents Event Tables