Windows Integrity Management Agents Reference

1 Management Agents Event Tables
Introduction
This reference guide describes the Windows System Log Event ID number, severity, and
description of events generated by HP Integrity Management Agents software. The Management
Agents are a group of services that run continuously in the background on HP Integrity servers
and report the status of system components.
Each Management Agent has its own unique table(s) in this document. Each row in Platform
Agent table #1 includes the following information about the event:
Windows System Log Event ID number (the table is sorted on this field, in ascending order)
Severity (Warning or Error)
Description
SNMP trap that generated the event
Each row in Platform Agent table #2 includes the following information about the event:
Windows System Log Event ID number (the table is sorted on this field, in ascending order)
Cause
Recommended Action
Each row in the remaining agent event tables includes the following information about the event:
Windows System Log Event ID number (each table is sorted on this field, in ascending order)
Severity (Informational, Warning, or Error)
Description
Platform Events Table 1 (Windows System Log Event ID, Severity,
Description, SNMP Trap)
SNMP Trap Generating This Event
Event Description
Event
Severity
Event
ID
HPTemperature - 4 in
HPIFP02TRAP.MIB
A temperature inside the server has gone
outside the factory specified range.Warning4
HPTemperature - 5 in
HPIFP02TRAP.MIB
A temperature inside the server has gone far
outside the factory specified range.Error5
HPTemperature - 6 in
HPIFP02TRAP.MIB
Temperature sensor crossed upper
non-recoverable thresholdError6
HPEnvironment - 8 in
HPIFP02TRAP.MIB
A measured voltage in the server has gone
far outside the factory specified lower voltage
range.Error8
HPEnvironment - 9 in
HPIFP02TRAP.MIB
Voltage sensor crossed lower non-recoverable
thresholdError9
HPEnvironment - 10 in
HPIFP02TRAP.MIB
A measured voltage in the server has gone
outside the factory specified upper voltage
range.Warning10
HPEnvironment - 12 in
HPIFP02TRAP.MIB
Voltage sensor crossed upper
non-recoverable thresholdError12
HPChassis - 26 in HPIFP02TRAP.MIB
The server's built-in sensors have detected
an open chassis door.Warning26
SystemHW - 76 in HPIFP02TRAP.MIBHot swap Cage: Drive removedError76
SystemHW - 113 in HPIFP02TRAP.MIBHot Swap Cage: SCSI cable removedWarning113
Introduction 7