Windows Integrity Management Agents Reference
update system firmware with new PAL that
support the PAL_SET_FEATURE call.
PAL does not support call to set the processor
feature set during processor rendezvous5686
Report the IP to the firmware team. Reset the
system. This cannot be worked around in the
field.5692
Load the Memory extenders according to the
users manual.
The memory extenders have not been loaded in
the correct order.5696
Upgrade system firmware.
New table entry types added by SAL not
understood by EFI.5698
Reboot. If problem persists contact your HP
representative for support.Table corrupted.5700
Reboot system. If problem persists, contact HP
support to troubleshoot the problem.Corrupted table.5701
Upgrade system firmware. If problem persists,
contact HP support to troubleshoot the problem.Inconsistency in EFI firmware.5704
examine preceding events for problem.Unknown.5708
If user requires Chipspare, replace the DIMM
with a x4 DIMM. If Chipspare is not required,
then no action is required.
User installed a x8 DIMM in a system configured
for chipspare.5711
Look at previous events and ASCII information
in this event for more information. If problem
persists, contact HP support to troubleshoot the
problem.The cause is unknown.5712
Check for user entering "break" command. Check
for shell scripts using the "break" command.Executing the "break command.5713
Reset the card containing the USB interface to
restart the controller. Contact your HP
representative to check the USB interface.Problem with USB controller.5714
Reboot. If problem persists contact your HP
representative for support.EFI/SAL firmware mismatch.5715
Reboot. If problem persists contact your HP
representative for support.
EFI unable to create internal event. EFI out of
resources.5717
Reboot. If problem persists contact your HP
representative for support.
Not all expected services are available. Mismatch
between EFI and SAL versions. Internal EFI error.5718
Reboot. If problem persists contact your HP
representative for support.Mismatch between EFI and SAL versions5719
Reboot. If problem persists contact your HP
representative for support.EFI/SAL handoff structure corrupted.5720
Upgrade system firmware.Reached unimplemented firmware.5721
Reset the BMC. Contact your HP representative
to check the BMC.BMC not functioning properly.5722
Reboot. If problem persists contact your HP
representative for support.Internal EFI error.5723
Upgrade system firmware.Internal system firmware error.5724
Upgrade system firmware. If problem persists,
contact HP support to troubleshoot the problem.
Multiple attempts to initialize system events, EFI
internal error.5725
Reboot system. Upgrade system firmware.Out of resources. Internal EFI error.5726
Platform Events – Table 2 (Windows System Log Event ID, Cause, Recommended Action) 79