Windows Integrity Management Agents Reference
Install memory ranks in pairs of DIMMs that are
the same size and DRAM width.
The user installed a mismatched pair of DIMMs
in the same rank (i.e. the DIMMs are different
size or DRAM width).5779
Reboot. If problem persists contact your HP
representative for support.Internal EFI error.5784
Reset BMC. Contact your HP representative if
problem persists.BMC not responding properly.5785
Reboot system.SAL storage corrupted.5786
Upgrade system firmware. If problem persists,
contact HP support to troubleshoot the problem.Internal EFI error.5787
Reboot or update System FW. If problem persists
contact your HP representative for support.
SFW has determined that the MDT table is
invalid.5788
Contact your HP representative for support.
A CPU has a fixed ratio that is incompatible with
the FSB frequency set in the chipset.5790
Look for events indicating incompatible or bad
CPUs and replace them. If problem persists
contact your HP representative for support.
The user or SFW has set all CPUs to be
deconfigured.5791
Validate all of the cells connectivity to the PD
Check the XBC chips seating reset the system
replace either cells/system backplaneAn XBC is indicating a port failure5793
Check crossbar and link specified in the event
data. Reset cell.Possible bad link, crossbar, or cell connection.5794
Install memory ranks in quads of DIMMs that
are the same size and DRAM width.
The user installed a mismatched quad of DIMMs
in the same rank (i.e. the DIMMs are different
size or DRAM width).5795
Firmware detected excessive errors on the DIMM
/ Replace the specified DIMM5796
Check XBC and port specified by event data.Possible firmware or link error.5797
Check for hardware errors. Reset cell.
Possible bad connection between cell and
backplane.5798
No action required.5799
Reconfigure the PD so that all cells have
processors running at the same speed.5800
A previously reported event may provide exact
details Reboot, if failure persists, then either
replace the CC chip or the system backplane.An error initializing fabric5802
Reset cellFirmware error5803
Reset cellFirmware error5804
Contact FW engineering. This is a bug.5805
Reset cell.Bad connection between XBC and cell.5806
Reset cellFirmware error.5807
Reset cell.Firmware error.5808
Reset cell.Bad connection between XBC and cell.5809
Reset cell.Bad connection between XBC and cell.5810
Reset BMC or reboot. Upgrade BMC FW and
System FW. If problem persists, contact your HP
representative for support.Problem accessing the BMC.5811
82 Management Agents Event Tables