Windows Integrity Management Agents Reference
Contact HP Support personnel to troubleshoot
problem
The CPU fan identified by the attached physical
location is not operating at expected speed.7893
Contact HP Support personnel to troubleshoot
problem
The CC chip fan identified by the attached
physical location has failed.7894
Contact HP Support personnel to troubleshoot
problem
The CC chip fan identified by the attached
physical location is not operating at expected
speed.7895
Use FWUU (Firmware Update Utility) to check
the revision numbers of PDHC and PDC
Firmware on the cell(s) called out in the event
log. Compare to other cells in the complex, or, if
single cell, check firmware revs. available to
FWUU.
(Probable) Either System firmware or PDHC
Firmware on the named cell was upgraded to a
new major revision number and not the other.
The major numbers must match when checked
by the PDHC or else the cell will not be allowed
to boot.7896
Update PDHC or MP firmware
PDH Controller firmware version is not
supported with this version of MP FW7902
Contact HP Support personnel to troubleshoot
the problem.
One or more of the DC to DC power converters
on the Cell Power Board is displaying a fault
condition.7903
See additional logs in determine why initialize
node failed. There could be a hardware or PAL
problem.7938
Inter-Processor-Interrupts may not be working,
or the command may have timed out. This could
be a firmware bug or hardware problem. Look
for other clues in the event log.7939
The CPU may be stuck waiting for a previous
command or may not be healthy. This could also
be caused by a system resource contention
problem.7940
PAL was unable to be successfully called. See
other event ids to determine if action needs to be
taken.7948
Load CPUs in order 0, 1, 2, 3.CPUs not loaded in correct order.7953
check CC, check link Check logs for other errors.
If error is persistent, replace cell boardthe link generated a new error7963
Unspecified7964
Either the MP is not present, or the requested
information does not exist. Ensure that the MP is
functioning and that the proper data is being
requested.7965
The MP is not present, may be out of space, or
the command was badly formatted. Ensure that
the MP has enough space and try again. If the
problem persists, contact engineering.7966
This is a bug, contact engineering7973
Either the GSP was not present or there was a
resource problem storing the variable. There
should be other clues in the event id log to
indicate which is the case. Restore the GSP.7974
Contact HP Support personnel to troubleshoot
the problemA power converter has failed.7975
Modify CPUProcConfigValue in /options to set
the correct bits.8009
Platform Events – Table 2 (Windows System Log Event ID, Cause, Recommended Action) 89