Windows Integrity Management Agents Reference

Contact HP support personnel to troubleshoot
the Cell Board and/or PDH Daughtercard
A hardware fault is preventing the PDH bus
semaphore from being taken/released as
expected.8151
Update PDHC FW, MP FW, System FW and the
OS IPMI driver to the latest revisions.
An unknown OS IPMI driver or Manageability
FW bug has occurred.8153
Reset the system. Clear SFW NVM. Upgrade
system firmware.
SAL service to read tokens not functioning
properly.8154
Validate all of the cells connectivity to the PD
Check the XBC chips seating reset the system
replace either cells/system backplaneAn XBC is indicating a port failure8156
Check for hardware failures. Reset backplane to
re-initialize fabric.Hardware failure: link, crossbar chip, or cell.8159
Contact HP Support Personnel to determine why
the backplane was unrecognized.An unrecognized backplane is installed.8184
Contact HP Support personnel to analyze the
fabric.CC Write Failure.8186
CC to XBC link init failure. Contact your HP
service representative to check the CC to XBC
link8187
CC to XBC link init failure. Contact your HP
service representative to check the CC to XBC
link8188
CC to XBC link init failure. Contact your HP
service representative to check the CC to XBC
link8189
CC to XBC link init failure. Contact your HP
service representative to check the CC to XBC
link8190
Contact HP Support personnel to analyze the
fabric.
The neighbor port is not routable. The port is
either: not connected, landmined, in FE, or
contains an SBE or LPE.8194
Contact HP Support personnel to analyze the
fabric.Fabric access error8195
Contact HP Support personnel to analyze the
crossbar.Possible crossbar failure8198
Upgrade PM firmware to latest revision. If
already at current revision, replace UGUY board.
Hardware in unknown state, or programming
bug found.8199
Upgrade PM firmware to latest revision. If
already at current revision, replace UGUY board.
Hardware in unknown state, or programming
bug found.8200
Contact your hp support representative.Debug event.8202
Check results from other cells connected to the
same XBC. Check CC, Check XBC, Contact HP
Support Personnel.
Either the CC failed to inject the errors, the XBC
failed to detect them, or PDC could not access the
XBC CSR.8205
Re-configure cabinet to use a valid cabinet
number8206
The reporting cell is at a different firmware
revision than the cell reported in the data field.
A PD cannot be established. Please reprogram
the 2 cells to the same firmware revision.8207
Replace the UGUY board.A hardware error has occurred.8212
Platform Events Table 2 (Windows System Log Event ID, Cause, Recommended Action) 91