Windows Integrity Management Agents Reference
Contact HP Support personnel to analyze the
fabric.Fabric AccessError. Couldn't write this XBC.8966
Contact HP Support personnel to check the CC
Probably an error reading the XIN. Look for
additional descriptive chassis codes.8968
Contact HP Support personnel to check the CC
Probably an error reading the XIN. Look for
additional descriptive chassis codes.8969
Hardware AccessError. Have your HP support
representative check the Coherency Controller
(CC).8970
Hardware AccessError. Have your HP support
representative check the backplane and
Coherency Controller (CC).8971
Ensure the cells are connected. Check historical
chassis codes from most recent boot to see if the
link had ever initialized. Have your HP support
representative check the backplane and
Coherency Controller (CC).8972
Ensure the cells are connected. Check historical
chassis codes from most recent boot to see if the
link had ever initialized. Have your HP support
representative check the backplane and
Coherency Controller (CC).8973
Contact HP Support personnel to analyze the
fabric, CC, Backplane.Hardware AccessError.8974
Contact HP Support personnel to check the XBC,
CC, backplanelink init problem8975
An unanticipated error occurred. Contact HP
Support personnel to analyze the IPMI FPL log.8976
A CPU is broken. Replace it.8979
No action is required. The problem has been
corrected by SFW.The RTC was invalid8981
This could be caused by an incompatibity
problem between PAL and the CPUs. Check that
PAL supports all the CPUs installed on the
system.8982
Look for adjacent chassis codes to determine the
cause of FabricWalk failure. Check the backplane
and fabric connectivity. Contact the HP Support
Personnel for further troubleshooting.8983
Most likely a failure on the fabric or on the CC.
Fabric failures should produce additional chassis
codes. If no additional chassis codes indicate the
cause of the failure, then contact the HP Support
Personnel for further troubleshooting.8984
Replace the DIMM flagged by SFWSFW detected a failing DIMM9000
The Cell board has a problem. Either the Real
Time Clock is not working properly or the system
is not being clocked at the value it thinks it is.9019
Check CC to CC link. Look for additional failure
chassis codes to provide more detail.Fabric Access Failure,9020
Run DC Connectivity test. Check flex cables,
XBCs, and CCs.link errors.9021
Platform Events – Table 2 (Windows System Log Event ID, Cause, Recommended Action) 97