HP Integrity rx2600 Server and HP Workstation zx6000 - Operations and Maintenance Guide, 2nd Edition (5969-3163)
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide 3–47
System Configuration
7KH%0&VXSSRUWVWKHYHUVLRQ,30,FDWHJRULHVDQGFRPPDQGVOLVWHGLQWKHIROORZLQJWDEOHV
)RUGHWDLOHGLQIRUPDWLRQRQWKH,30,VSHFLILFDWLRQDQGFRPPDQGVVHHWKH,QWHOZHEVLWH
http://www.intel.com/design/servers/ipmi
Command Categories
Chassis Commands
Sensor/Event Commands
NetFn NetFn << 2 Description
00, 01 00, 04 Chassis
04, 05 10, 14 Sensor/Event (S/E)
06, 07 18, 1C Application
0A, 0B 28, 2C Storage
32, 33 C8, CC HP Custom (proprietary)
Command Description
01h Get chassis status
02h Chassis control
0Fh Get power-on hours (POH) counter
06h Set power restore policy
Command Description
01h Get event receiver
02h Platform event (a.k.a. “Event Message”)
28h Set sensor event enable
29h Get sensor event enable
2Ah Re-arm sensor events
2Dh Get sensor reading