Event, Error and Warning Messages
Events Without Sensors
7KH%0&ORJVWKHVHHYHQWVZLWKD¦VHQVRUQXPEHU§RIWKHUHLVQRPDWFKLQJ6'5HQWU\
Triplet Event data2 data3 Notes
10:70:64 SEL almost full 1F %full The BMC logs this when the SEL is
75% full
12:70:04 BMC entering firmware
update mode
12:70:05 SFW flash lnlock System firmware update in
progress
12:70:06 Front panel lock Disables all power and reset
requests from ipmi or sensors
12:F0:06 Front panel unlock
12:70:07 Firmware update app:
starting component cpdate
12:F0:07 Firmware update app:
ending comionent update
12:70:80 BMC entering special
mode
Mode – Mode is a bit-map:
Bit 0: Shmoo
Bit 1: MfgTest
Bit 2: Shutdown override
Bit 3: Fixed fan speed
Bit 4: Mfg
Bits 7-5: unused, set to 0
12:70:A1 BMC firmware initializing Major FW
rev
Minor
FW rev
1D:70:00 BMC cold reset
1D:70:01 BMC warm reset
1D:70:02 BMC cold reset after SDRR