hp workstations zx6000, hp server rx2600 - operation and maintenance guide
Troubleshooting
Using the System’s LEDs and e-buzzer to Troubleshoot
Chapter 4
156
System Board Diagnostic LEDs
There are three additional LEDs that can help when troubleshooting the system. These
LEDs are locate on the system board close to the back of the system and can be viewed
through the small cooling holes in the system backplane.
Figure 4-7 Location of the STBY LED, F/W LED and BMC LED
F/W LEDBMC LED
STBY LED
Look through
Look through here
for the F/W and
BMC LEDs
here for the
STBY LED
Table 4-2 Description of the System Board LEDs
LED’s Name Description
STBY This standby LED comes on as soon as the system’s power cord is plugged
in. If this light is off when you plug it in, reseat the power supply, and if this
does not work, replace the power supply. See Chapter 2 for instructions.
BMC A few seconds after the system is plugged in this LED starts blinking, which
means that the Baseboard Management Controller is alive. If this LED is
not blinking and the STBY (standby)LED is on, you may have to replace the
system board.
F/W A few seconds after the system button is pressed in the system firmware
code fetch LED comes on indicating that the firmware has started the boot
process. If this LED does not come on, you may have to replace the system
board.