hp workstations zx6000, hp server rx2600 - operation and maintenance guide
Event, Error and Warning Messages
EFI Error and Warning Messages
Appendix D
202
EFI Error and Warning Messages
This section provides the EFI error and warning messages for your system. includes the
error number, error or warning message and a solution if available.
Table D-1 EFI Error and Warning Messages
Error Number Error/Warning Message Solution
0 Error initializing LDB —
2 Insufficient resources to assign to one or
more I/O devices
—
3 Failed I/O slot(s) deconfiguration —
4 Unexpected hardware I/O configuration —
7 No BMC installed in platform Ensure the BMC ROM is
installed; update BMC firmware
8 BMC cannot be accessed Check BMC logs for errors
9 One or more BMC ports failed —
10 BMC system event log is full Clear SEL
11 Platform Scr is bad —
12 Set time to BMC SEL failed —
13 SEL get info failed —
14 Initial BMC SEL event failed —
15 Update of BMC buffered data failed —
16 All ACPI BMC ports bad —
17 Read error on BMC token —
18 BMC token transmit checksum error —
19 Error writing BMC token on download —
20 NVM token access error —
21 BMC token write error during NVM write
through
—
22 Error reading BMC token on upload to
NVM
—
23 Error reading BMC first boot token —
24 Primary FIT failed Reflash firmware
25 Secondary FIT failed Reflash firmware
26 PAL_A warning. One copy of PAL is bad —