hp workstations zx6000, hp server rx2600 - operation and maintenance guide
Event, Error and Warning Messages
Sensor Data Record Repository (SDRR)
Appendix D
218
Power Supply Status SDRs (Sensors 0x40-0x42)
This sensor tracks the status of the power supplies. It supports deassertions and
readings (see below for the list of supported events). The BMC reports whether it has
enabled/disabled the supplies using sensors 0x43-0x45.
The Everest power supplies do not report “A/C lost” as a separate event, but as a generic
“failure detected” event.
Field Name Value Notes
SDR Type 0x02 Compact sensor record
Entity ID 0x0A Power supply
Entity Instance 0x01-0x02
Sensor Initialization 0x03 Sensor events+scanning enabled at BMC reset
Sensor Capabilities 0xC0 Ignore sensor = yes
Auto-rearm = yes
Hysteresis = none
Thresholds = none
Event Message Control support = per event
Sensor Type 0x08 Power Supply
Event/Reading Type Code 0x6F Sensor-specific
Assertion Event Mask 0x000B 0x00: presence detected
0x01: power supply failure detected
0x03: power supply A/C lost
Deassertion Event Mask 0x000B
Discrete Reading Mask 0x000B
String “Power Supply x” x = 0, 1, or 2 (nothing on this system)
Triplet Event
08:6F:0 Power supply inserted
08:6F:1 Power supply failure detected
08:6F:3 Power supply A/C lost
08:EF:0 Power supply removed
08:EF:1 Power supply failure ended
08:Ef:3 Power supply A/C restored