hp workstations zx6000, hp server rx2600 - operation and maintenance guide
Event, Error and Warning Messages
Sensor Data Record Repository (SDRR)
Appendix D
219
Power Supply Control SDRs (Sensor: 0x44-0x45)
This sensor tracks the state programmed by the BMC to the power supplies, using the
PSUx_ON signals.
Events:
Field Name Value Notes
SDR Type 0x02 Compact sensor record
Entity ID 0x0A Power supply
Entity Instance 0x01-0x02
Sensor Initialization 0x03 Sensor events+scanning enabled at BMC reset
Sensor Capabilities 0xC0 Ignore sensor = yes
Auto-rearm = yes
Hysteresis = none
Thresholds = none
Event Message Control support = per state
Sensor Type 0x08 Power Supply
Event/Reading Type Code 0x09 Discrete – enabled/disabled
Assertion Event Mask 0x0003 0x00: device disabled
0x01: device enabled
Deassertion Event Mask 0x0000
Discrete Reading Mask 0x0003
String “Pwr Spply x Ctrl”
“Power Control”
x = 1 or 2
Triplet Event
08:09:00 Power supply turned off
08:09:01 Power supply turned on