hp workstations zx6000, hp server rx2600 - operation and maintenance guide
Product Information
Specifications and Characteristics
Chapter 1
22
If an overload triggers the power supply’s overload protection, the system is immediately
powered off. To reset the power supply unit:
1. Disconnect the power cord.
2. Determine what caused the overload by contacting an HP Support Representative.
3. Reconnect the power cord, and reboot the workstation.
If an overload occurs twice, then there is an undetected short circuit somewhere.
When you use the front panel's power button to turn off the workstation, power
consumption falls below the low power consumption (refer to the table on page 23), but
doesn't reach zero. To reach zero power consumption in “off” mode, either unplug the
workstation or use a power block with a switch.
Parameter
Total Rating
a
a. The Total Ratings are for a system configuration with two 1GHz processors, 12 DDR
SDRAM (512MB each), three 36GHz hard disk drives, one FireGL 4 graphics card
and one LVD SCSI card.
Peak
(15 secs.)
Maximum
per PCI-X
Slots
64-bit,
133MHz
Maximum
for AGP
Slot
Standard
Connector
Input voltage 100-127
VAC
200-250
VAC
Off Off Off
Input current (max) 7.2 A 3.6 A Off Off Off
Input frequency 50 to 60 Hz Off Off Off
Measured input power 560 W Off Off Off
Available power
(output)
600 W Off 85W total for PCI slots and
AGP slot
Max current at +12 V 49 A Off 0.5 A 4.8 A
Max current at -12 V 0.35 A Off 0.1 A N/A
Max current at +3.3V 34 A Off 4.6 A 12.1 A
Max current at +5V 18 A 31 A 3 A 2 A
Max current at +3.3V
stdby
3.5 A Off Off