hp workstations zx6000, hp server rx2600 - operation and maintenance guide
Event, Error and Warning Messages
Sensor Data Record Repository (SDRR)
Appendix D
220
Power Unit Redundancy SDR (Sensor 0x4F)
This sensor tracks the redundancy of the power unit. If one redundant supply goes down,
a “redundancy lost” event is logged. There is no “redundancy degraded” state, since one
of the two power supplies is needed to operate.
Events:
PGOOD Voltage SDRs
Field Name Value Notes
SDR Type 0x02 Compact sensor record
Entity ID 0x13 Power Unit
Entity Instance 0x01
Sensor Initialization 0x03 Sensor events+scanning enabled at BMC reset
Sensor Capabilities 0x42 Ignore sensor = no
Auto-rearm = yes
Hysteresis = none
Thresholds = none
Event Message Control support = global disable
only
Sensor Type 0x09 Power Unit
Event/Reading Type Code 0x0B Redundancy
Assertion Event Mask 0x0003 0x00: Redundancy Regained
0x01: Redundancy Lost
Deassertion Event Mask 0x0000
Discrete Reading Mask 0x0003
String “Power
Redundancy”
Triplet Event
09:0B:00 Power redundancy regained
09:0B:01 Power redundancy lost
Field Name Value Notes
SDR Type 0x02 Compact sensor record
Entity ID variable
Entity Instance variable
Sensor Initialization variable