hp workstations zx6000, hp server rx2600 - operation and maintenance guide
Event, Error and Warning Messages
Sensor Data Record Repository (SDRR)
Appendix D
221
These sensors are used to log failing PGOOD signals. When one of these signals fails, the
BMC logs a transition event and initiates an emergency power-off.
DC sensors:
Events:
Sensor Capabilities 0x40 Ignore sensor = no
Auto-rearm = yes
Hysteresis = none
Thresholds = none
Event Message Control support = per event
Sensor Type 0x02 Voltage
Event/Reading Type Code 0x07 Discrete - severity
Assertion Event Mask 0x0008 0x03: transition to non-recoverable from less
severe
Deassertion Event Mask 0x0000
Discrete Reading Mask 0x0008
String “”
Field Name Value Notes
Number
Entity
ID
Entity
Instance
Sensor
Init
Sensor
Cap
String
0xCD 0x0A 0x01 0x00 0xC0 12V Pwr Supply 1
0xCE 0x0A 0x02 0x00 0xC0 12V Pwr Supply 2
0xCF 0x15 0x01 0x00 0x40 12V Rail 0
0xD0 0x15 0x01 0x00 0x40 12V Rail 1
0xD1 0x15 0x01 0x00 0x40 12V Rail 2
0xD2 0x15 0x01 0x00 0x40 12V Rail 3
0xD3 0x15 0x01 0x00 0x40 12V Rail 4
0xD5 0x07 0x01 0x00 0x40 Over-Voltage
0xD6 0x07 0x01 0x00 0x40 Power Good
Triplet Event
02:07:03 Voltage reached critical level