hp workstations zx6000, hp server rx2600 - operation and maintenance guide

Event, Error and Warning Messages
Sensor Data Record Repository (SDRR)
Appendix D
224
Ambient Temperature SDR (Sensor 0xD8)
This sensor returns the current ambient temperature, and logs all upper threshold
events. Note that the actual sensor is an LM75.
Field Name Value Notes
SDR Type 0x01 Full sensor record
Entity ID 0x17 System chassis
Entity Instance 0x01
Sensor Initialization 0x00 Sensor events+scanning disabled at BMC reset
Sensor Capabilities 0x55 Ignore sensor = no (0)
Auto-rearm = yes (1)
Hysteresis = readable (01)
Thresholds = readable (01)
Event Message Control support = entire sensor
only (01)
Sensor Type 0x01 Temperature
Event/Reading Type Code 0x01 Threshold
Lower Threshold Reading Mask 0x0FC0 b6-b11: assertion events on all upper thresholds
Upper Threshold Reading Mask 0x4000 b14: upper non-recoverable threshold
comparison is returned
no deassertion events
Settable/Readable Threshold
Mask
0x0020 b5: upper non-recoverable threshold is readable
Positive-going threshold
hysteresis
3 C
String Ambient Temp”
Triplet Event data2 data3
01:01:52 Temperature too low (critical) Reading Threshold
01:01:54 Temperature too low (non-recov) Reading Threshold
01:01:56 Temperature (OK from non-crit) Reading Threshold
01:01:57 Overtemperature (non-critical) Reading Threshold
01:01:58 Temperature (OK from critical) Reading Threshold
01:01:59 Overtemperature (critical) Reading Threshold
01:01:5A Temperature (OK from
non-recov)
Reading Threshold
01:01:5B Overtemperature (non-recov) Reading Threshold