hp workstations zx6000, hp server rx2600 - operation and maintenance guide
Event, Error and Warning Messages
Sensor Data Record Repository (SDRR)
Appendix D
226
Fan Tach SDRs (Sensors 0xE0-0xE7)
These sensors report current fan speeds. They do not generate events – the “fan health”
sensors do.
Field Name Value Notes
SDR Type 0x01 Full sensor record
Entity ID 0x1D Fan
Entity Instance 0x01-0x08
Sensor Initialization 0x00 Sensor events+scanning disabled at BMC reset
Sensor Capabilities 0x43 Ignore sensor = no
Auto-rearm = yes
Hysteresis = none
Thresholds = none
Event Message Control support = entire device
only
Sensor Type 0x04 Fan
Event/Reading Type Code 0x01 Threshold
Assertion Event Mask 0x0000
Deassertion Event Mask 0x0000
Discrete Reading Mask 0x0000
String ”Fan 1R (Power)”
“Fan 1L (Power)”
Fan CPU0 (R)
Fan CPU1 (L)
Fan 2F (Memory;
rx2600 only)
Fan 2B (Memory;
rx2600 only)
Fan 2 (Memory;
zx6000 only)
Fan 3F (Disk)
Fan 3B (Disk)
“Fan 1 (Bottom)”
“Fan 2 (Top)”
“Processor Fan”