hp workstations zx6000, hp server rx2600 - operation and maintenance guide
Event, Error and Warning Messages
Sensor Data Record Repository (SDRR)
Appendix D
229
SCSI Cable Presence SDR (Sensors 0xF4-0xF6)
These sensors track cable presence on each of the three SCSI channels. An assertion
event is logged each time the external cable is added/removed (no events are generated
for the internal cables). Readings indicate whether a cable is currently present.
The actual detection is done through an 8575 expander on the SCSI backplane, which is
powered by V5P0, not standby voltage therefore, when power is off, these sensors must
return no reading at all (i.e. completion code 0xCE).
Events (sensor 0xF6 only):
Field Name Value Notes
SDR Type 0x02 Compact sensor record
Entity ID 0x1F Cable
Entity Instance 0x01-0x03
Sensor Initialization 0x00 Sensor events+scanning disabled at BMC reset
Sensor Capabilities 0x42 Ignore sensor = no
Auto-rearm = yes
Hysteresis = none
Thresholds = none
Event Message Control support = global disable
only
Sensor Type 0x1B Cable
Event/Reading Type Code 0x08 Discrete – presence
Assertion Event Mask 0x0000,
0x0003 (0xF6)
0x00: device absent
0x01: device present
Deassertion Event Mask 0x0000
Discrete Reading Mask 0x0003
String “SCSI Cable x” x= ChA, ChB, ExtCh
Triplet Event
1B:08:00 External SCSI cable removed
1B:08:01 External SCSI cable connected