hp workstations zx6000, hp server rx2600 - operation and maintenance guide
Event, Error and Warning Messages
Sensor Data Record Repository (SDRR)
Appendix D
234
Events without Sensors
The BMC logs these events with a “sensor number” of 0; there is no matching SDR.
FRU Device Locator Records
These records are used to indicate that some entities should be detected by looking at
their FRU devices. If the FRU inventory device is present, then the entity is present too.
The “device string” in the locator record is also useful to distinguish between entities.
Note: the “Device Type Modifier” byte is used to indicate the FRU data format, as per
[IPMI 1.5] ([IPMI 1.0] says that this byte should be set to 0x00 for a logical FRU device).
Triplet Event data2 data3 Notes
10:70:64 SEL almost full 1F %full The BMC logs this when the SEL is 75%
full
12:70:80 BMC entering special
mode
Mode – Mode is a bit-map:
Bit 0: Shmoo
Bit 1: MfgTest
Bit 2: Shutdown override
Bit 3: Fixed fan speed
Bit 4: Mfg
Bits 7-5: unused, set to 0
12:70:A1 BMC firmware initializing Major
FW rev
Minor
FW rev
1D:70:00 BMC Cold Reset
1D:70:01 BMC Warm Reset
1D:70:02 BMC Cold Reset after
SDRR update
FRU Format Device Type Modifier
IPMI 0x00
DIMM Memory ID 0x01
FRU Inventory 0x02
System processor cartridge FRU/PIROM (Processor Information ROM) 0x03