1
Figure 15: RAID Cable Routing through the PCI Cage Board Cover
11. Place the PCI cage back into the system. Note that the RAID cable(s) must be flush
against the server chassis as it exits the PCI cage cable channel (see 1 in Figure 16). It
must then be routed around the chassis side of fan 3 to the hard drive backplane (see 2 in
Figure 16) to avoid crimping.
1
2
Figure 16: RAID Cable Routing
12. Connect the free end(s) of the RAID cable from the HP NetRAID-2M to the backplane.
The cable connectors are marked.
13. Reinstall the Management card and power supply connectors.
14. Reinstall any removed DIMMs into the memory banks.
15. Lower the fan power bridge.
16. Reinstall fans 2 and 3.
17. Close the server.