Internal Cabling Guide for NetRAID-2M on an HP Server rx2600[HP S&C DVD 1.03]
Cabling the HP NetRAID-2M to the Server
Default SCSI Cabling
If the HP NetRAID-2M is not already installed in your server from the factory, then the
internal hard drives for the rx2600 are connected to the integrated SCSI controller with two
internal SCSI cables attached to the system board and the hard drive backplane.
• One internal SCSI cable (p/n A7231-63017) is connected to the CH A connector of the
hard drive backplane. This connector is cabled to physical drives 0 and 1 (see Figures 5
and 6).
• The other SCSI cable (p/n A7231-63018) is connected to the CH B connector of the hard
drive backplane. This connector is cabled to physical drive 2 (see Figures 5 and 6).
A
B
Figure 5: Default Cabling for Internal Hard Drives
2
1
0
B
A
Figure 6: Physical Drive Location (front of server)
8
HP CONFIDENTIAL Codename: Longs Peak Part Number: 5971-4217 Last Saved On: 4/2/03 2:24 PM