Internal Cabling Guide for NetRAID-2M on an HP Server rx2600[HP S&C DVD 1.03]
Figure 9: Lifting the Fan Power Bridge
4. Unplug one or both of the SCSI cables connected to the hard drive backplane (see Figure
5), depending upon whether you want to use one or both channels of the HP NetRAID-
2M.
Single Channel: Unplug the backplane SCSI cable channel A (bottom) connector.
Dual Channel: Unplug the backplane SCSI cable channel A (bottom) and SCSI cable
channel B connectors.
5. Remove any unused internal SCSI cables from the server, since these cables are not
terminated and may not remain connected to the system board. Additionally, enough
room is not available for the cables to be left unplugged in the server.
To remove unused SCSI cables, you must first remove any DIMMs in memory banks A
and B (closest to the PCI cage).
6. Remove the ECI Management card by first disconnecting all power cables and any LAN
or telecommunications cables.
7. Use a T-15 Torx driver to unscrew the two power connector mounting screws and
remove the power connectors from the back of the system. See Figure 10.
Figure 10: Removing the Power Connectors
8. Disconnect the Management card (orange) connector, then remove the Management card
from the system by grasping it by its edges. Once removed, place the Management card
on the anti-static bag that the HP NetRAID-2M came in to protect it from static
electricity. See Figure 11.
10
HP CONFIDENTIAL Codename: Longs Peak Part Number: 5971-4217 Last Saved On: 4/2/03 2:24 PM