Management Processor Card Firmware Upgrade Product Update - HP integrity rx2600 and HP integrity rx5670

Management Processor Card Firmware
FP: FRONT PANEL PROCESS
Chapter 1
7
FP: FRONT PANEL PROCESS
This command allows the modification of the state of the front panel. Specifically, it provides the ability to
turn off the Fault and Attention LEDs, as well as turn on/off the Locator LED.
Menu-Based Command
To modify the front panel using the menu-based commands, complete the following procedure:
MP Host Name: hqiasle8
MP:CM> FP
This command allows a user modify the state of the front panel.
LEDs: SYSTEM POWER
FLASH YELLOW ON
LED State: Running non-OS code. Non-critical error detected.
Check Events and Console Logs for error messages.
Current Front Panel State:
- - Fault Condition : Off
W - Attention Condition : On
L - Locator LED : Off
Enter parameter(s) to change, A to modify All, or [Q] to Quit: A
For each parameter, enter:
New value, or <CR> to retain the current value, or
DEFAULT to set the default value, or
Q to quit
Attention Condition:
Current -> - - - On
OFF - Off
Enter new value, or [Q] to Quit: OFF
-> Attention Condition will be updated.
Locator LED State:
ON - On
Current -> OFF - Off
Enter new value, or [Q] to Quit: ON
-> Locator LED State will be updated.
New Front Panel State (* modified values):
- - Fault Condition : Off
* W - Attention Condition : Off
* L - Locator LED : On
Enter parameter(s) to change, Y to confirm changes, or [Q] to Quit: Y
-> Front Panel State has been updated.
LEDs: SYSTEM POWER