Operations and Maintenance Guide, Second Edition - HP Integrity rx2600 Server and HP zx6000 Workstation

104 HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Removing and Replacing Components
3. Replace the server covers, reconnect all of the power and external cables and power on the
server.
Verify that the battery has been installed correctly:
Run the time and date commands at the EFI shell prompt or,
On servers with firmware version 2.0 or higher, adjust the time and date settings using
the EFI
System Configuration menu.
You may need to reset the system time and date using the EFI time and date commands.
Once you have set the time, power the server off, unplug the power cord, and wait for a
minute before turning it back on. Run the time and date commands again. If the time and
date are now correct, you have installed the battery correctly.
Removing the iLO MP Card Battery
To remove the iLO MP card battery, follow these steps:
1. Remove the iLO MP card from the server.
2. Lift up on the battery and push on the back of it with a small flat-head screwdriver. This
removes the battery from its holder.
CAUTION: Lift the battery just high enough to clear its holder. Too much stress on the battery holder
retaining clip may break it.
Remove the iLO MP Card Battery
Replacing the iLO MP Card Battery
To replace the iLO MP card battery, follow these steps:
1. Lift up on the battery holder retaining clip with a small flat-head screwdriver and slide the
battery into its holder. The positive
(+) side of the battery should face up.
CAUTION: Lift the battery just high enough to clear its holder. Too much stress on the battery holder
retaining clip may break it.
2. Re-install the iLO MP card in the server.
3. Replace the server covers.
4. Reconnect all of the power and external cables.
Power Supply Interface Module
The power supply interface (PSI) module supports up to two redundant power supplies.
+