Operations and Maintenance Guide, Second Edition - HP Integrity rx2600 Server and HP zx6000 Workstation

106 HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Removing and Replacing Components
Replacing the Power Supply Interface Module
2. Screw in the PSI module mounting screw (1) and secure the power cables behind the holding
clips (2).
Securing the Power Supply Interface Module and Cables
3. Replace the system board.
4. Replace the server covers.
5. Reconnect all of the power and external cables.
Hard Drive Backplane
The hard drive backplane provides connectors for three hard disk drives.
Removing the Hard Drive Backplane
To remove the hard drive backplane, follow these steps:
1. Power off the server, disconnect all power and external cables, and remove the server covers.
2. Lift up on the PCI/AGP cage release lever and the back edge of the PCI/AGP cage and lift
the PCI/AGP cage out of the server.
3. Lift up on the fan power bridge (1) and disconnect the backplane power cable (2).
1
2