Operations and Maintenance Guide, Second Edition - HP Integrity rx2600 Server and HP zx6000 Workstation

HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide 121
Troubleshooting
BMC Faults
BMC firmware is damaged Power off and unplug
the server. Wait 20
seconds, then plug in
and restart the server. If
the error repeats,
replace the system
board.
System board FRU inventory
device inaccessible
Replace the system
board.
Temperature Faults
External air temperature too
high
Make sure nothing is
blocking the airflow.
Place the server in an
air-conditioned room.
Power Supply Errors
VRM or power pod fault
View the SEL for
additional information.
For more help, contact
your HP Support
Engineer.
Power Supply 1 fault
Power Supply 2 fault
Replace the power
supply.
12V out of range (power supply
interface fault)
System
LED LED1 LED2 LED3 LED4 Problem Solution